7-7
CONNECTION OF SERVICES
High Level Ventilation
High level ventilation is provided by the roof
vents. The ventilation provided has been
carefully calculated and relates to the rating
of the appliances in the vehicle. Roof vents
must not be covered with anything that may
limit or affect the ventilation they provide.
Maintenance
Under no circumstances should any fixed
ventilation aperture be blocked, covered,
either partially or fully, or be modified in any
manner whatsoever. They should be checked
at least annually for damage or blockage.
Screens and/or grilles should be kept clean
and free from dust. See diagram of upper/
lower ventilation.
All ventilation complies with BS EN 721 and
vents should not be obstructed in any
manner as this could lead to insufficient fresh
air. In this case the confined atmosphere
becomes depleted of oxygen which leads to
the formation of the highly poisonous gas
‘carbon monoxide’. Carbon Monoxide is
odourless, colourless and tasteless and will
rapidly cause unconsciousness and death
with little or no warning prior to collapse.
THERE IS NO DANGER WHEN ADEQUATE
VENTILATION IS PROVIDED.
When you are cooking, it is essential to
provide additional ventilation such as opening
windows near grill, cooker or oven.
Roof-mounted Flue installations
All flue installations should be inspected once
a year throughout their length for corrosion.
Flues should be replaced if any sign of
perforation is found. Ensure that the
replacement is of an approved type.
WARNING:
Never allow modification of
LPG systems and appliances except by
qualified persons.
Connection
Ensure that the gas regulator is correctly
connected to the gas cylinder in gas bottle
compartment and that the hose is tight.
Before turning on the gas supply, ensure that
all gas operated equipment in the motorhome
is turned off.
All gas equipment is supplied through a
central Gas Manifold System which has
individual isolation taps for each appliance
denoted by a symbol (see below).
WARNINGS:
1
Interior outlet sockets must only be
used with original appliances supplied
by manufacturer.
2
No appliance must be used outside
when connected to an internal socket.
3
No additional appliance must be used
inside the motorhome.
Gas isolation valve
Note:
Amount and order of taps may vary from that
which is shown.
Summary of Contents for lancashire ek
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 70: ...7 46 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 104: ...9 30 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT LANCASHIRE EK ES ...
Page 105: ...9 31 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT LANCASHIRE EL ...
Page 110: ...9 36 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE EK ...
Page 111: ...9 37 FITTED EQUIPMENT SINGLE BED ASSEMBLY LANCASHIRE EK ...
Page 112: ...9 38 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE EK ...
Page 113: ...9 39 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE ES ...
Page 114: ...9 40 FITTED EQUIPMENT BENCH SEAT SETTEE ASSEMBLY LANCASHIRE ES ...
Page 115: ...9 41 FITTED EQUIPMENT SINGLE BED ASSEMBLY LANCASHIRE ES ...
Page 116: ...9 42 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE ES ...
Page 117: ...9 43 FITTED EQUIPMENT OVERCAB BED LANCASHIRE ES ...
Page 118: ...9 44 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE EL ...
Page 119: ...9 45 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE EL ...
Page 132: ...11 2 USEFUL INFORMATION Superior craftsmanship within your reach at a dealer near you ...
Page 142: ...12 10 SERVICE DETAILS ...
Page 144: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 205136 HB1096 MY 2011 Ref 21234 ...