CONNECTION OF SERVICES
3.2 Residual Current Device & Miniature Circuit Breakers
The Residual Current Device (RCD) is basically
provided to protect the user from lethal electric
shock. The RCD will turn off (trip) if the current
flowing in the live conductor does not fully return
down the neutral conductor, i.e. some current is
passing through a person down to earth or
through a faulty appliance.
To ensure the RCD is working correctly, the test
button should be operated each time the vehicle
is connected to the mains supply (see section 5.1)
The Miniature Circuit Breakers (MCB’s) operate in
a similar way to traditional fuses and are provided to protect the wiring installation from overload
or short circuit. If an overload occurs the MCB will switch off the supply. If this occurs you should
investigate the cause of the fault before switching the MCB back on.
The following table shows the rating and circuit allocation for the three MCB’s
3.3 System Monitor
The system monitor circuit checks the power supply key components to
ensure optimum operation. The current status is displayed on the front of
the PSU by the means of a dear indication that illuminates in different
colours depending on the PSU status.
MCB
Rating
Wire Colour
Description
1
10 Amps
White
230v Sockets
2
10 Amps
White (Yellow for heater)
Extra 230v Sockets / Heater
3
6 Amps
Black (Blue for water heater)
Fridge/Water Heater / 12v Charger
(internally connected)
Mains supply on, PSU status good.
Mains supply off, PSU status good.
Mains supply on, PSU in warning mode. In this mode the PSU will limit
the output current to protect the unit from damage. It is still safe to use
the unit but the fault should be investigated. Typical causes are battery
temperature sensor unplugged, cooling fan not working, internal
sensors disconnected or failed.
Mains supply off, PSU in warning mode.
Mains supply on, PSU in overheat failure mode. In this mode the PSU
will shutdown and all equipment will be switched off. The cooling fan
will continue to run until the unit cools down. Typical causes are short-
circuited DC output, battery connected in reverse, cooling fan failed,
cooling vents blocked / covered, problem caused by prolonged use in
warning mode.
Mains supply on, PSU in overheat failure mode.
Mains supply off, PSU in overheat failure mode.
Indication description
Right
Status
Left
Centre
Good
Good
Warning
Warning
Failure
Failure
Failure
–
–
–
–
–
G
G
G
G
R
R
R
O
O
O
O
–
–
–
–
–
Summary of Contents for lancashire ek
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 70: ...7 46 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 104: ...9 30 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT LANCASHIRE EK ES ...
Page 105: ...9 31 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT LANCASHIRE EL ...
Page 110: ...9 36 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE EK ...
Page 111: ...9 37 FITTED EQUIPMENT SINGLE BED ASSEMBLY LANCASHIRE EK ...
Page 112: ...9 38 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE EK ...
Page 113: ...9 39 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE ES ...
Page 114: ...9 40 FITTED EQUIPMENT BENCH SEAT SETTEE ASSEMBLY LANCASHIRE ES ...
Page 115: ...9 41 FITTED EQUIPMENT SINGLE BED ASSEMBLY LANCASHIRE ES ...
Page 116: ...9 42 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE ES ...
Page 117: ...9 43 FITTED EQUIPMENT OVERCAB BED LANCASHIRE ES ...
Page 118: ...9 44 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE EL ...
Page 119: ...9 45 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE EL ...
Page 132: ...11 2 USEFUL INFORMATION Superior craftsmanship within your reach at a dealer near you ...
Page 142: ...12 10 SERVICE DETAILS ...
Page 144: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 205136 HB1096 MY 2011 Ref 21234 ...