12-6
SERVICE DETAILS
SECTION 9 - WATER SYSTEM
Before operating the water system, a visual
check of the following items may show up an
obvious leak source...
Fresh Water Tank
Check condition, fill tank and check for leaks.
Check the external filler and filler pipe to tank.
Check for satisfactory venting.
Check condition and presence of filler cap.
Waste Water Tank
Check drain tap is clear and working.
Check condition and presence of drain hose.
(The water tank will be drained, flushed,
cleaned and charged with a measure of toilet
fluid/disinfectant at the prior request of the
customer).
Pump Filter
When applicable, remove filter and replace.
Check the in-line pump for security and
condition. Remove the submersible pump
from tank, check condition.
Check pump inlet and outlet are clear and not
obstructed.
Check delivery hose and electric cable are
secure and satisfactory.
System Check
Operate pump. Check all piping for leaks.
Operate taps and shower. If a hot water
system is fitted, it can be checked for leaks
etc., using cold water. (Note: Aerated water
from tap could be due to a leak on the
suction side of the pump).
Waste Water System
With water running through the drain pipes,
check for leaks and satisfactory draining of
water from sinks etc.
Couplings and Fluids
Check that the appropriate markings are
used - blue for fresh water, grey for waste
water. Ensure a sealing off cover is supplied
for each coupling.
Check that filler positions are designated
“petrol”, “diesel” or “water” as appropriate.
Toilet Waste Tank
Check that any fixed tank intended to receive
discharge from a toilet is fitted with either a
level or full indicator.
SECTION 10 - ELECTRICAL
SYSTEMS
Extra Low Voltage 12 Volts (excluding
vehicle)
Battery/ies:
•
Check battery/ies for condition.
•
Check connections, wires, fuses and
relays appertaining to the habitation
electrics.
Wiring:
•
Examine all visible wiring.
•
Check all connections and joints are
sound and satisfactory.
Fuses/Fuse Holders:
•
Ensure that fuses and fuse holders used
to protect the habitation electrics are
satisfactory and that fuse ratings are
compatible with the circuit appliances
being protected.
Appliances:
•
Inspect all appliances for damage, signs
of overheating and secure fixing.
Function test all appliances.
Mains 230 Volt System
It is recommended that the inspection and
certification of the 230 volt system be carried
out by a qualified electrician who is an
approved contractor of the NICEIC (National
Inspection Council for Electrical Installation
Contracting) or a member of the Electrical
Contractors Association.
Summary of Contents for lancashire ek
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 70: ...7 46 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 104: ...9 30 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT LANCASHIRE EK ES ...
Page 105: ...9 31 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT LANCASHIRE EL ...
Page 110: ...9 36 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE EK ...
Page 111: ...9 37 FITTED EQUIPMENT SINGLE BED ASSEMBLY LANCASHIRE EK ...
Page 112: ...9 38 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE EK ...
Page 113: ...9 39 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE ES ...
Page 114: ...9 40 FITTED EQUIPMENT BENCH SEAT SETTEE ASSEMBLY LANCASHIRE ES ...
Page 115: ...9 41 FITTED EQUIPMENT SINGLE BED ASSEMBLY LANCASHIRE ES ...
Page 116: ...9 42 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE ES ...
Page 117: ...9 43 FITTED EQUIPMENT OVERCAB BED LANCASHIRE ES ...
Page 118: ...9 44 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE EL ...
Page 119: ...9 45 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE EL ...
Page 132: ...11 2 USEFUL INFORMATION Superior craftsmanship within your reach at a dealer near you ...
Page 142: ...12 10 SERVICE DETAILS ...
Page 144: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 205136 HB1096 MY 2011 Ref 21234 ...