7-24
CONNECTION OF SERVICES
Fault
Possible Cause
Proposed Fix
Control Panel
Control Panel current
Re-calibrate the current sensor as follows:
Problems
current reading
With the charger switch turned off, and the power turned off at the
(continued)
incorrect.
control panel (no LED’s on).
Scroll down
the display until battery current is shown.
Hold down the select button
(left arrow) until ‘calibrating . . . ‘
appears; keep the button pressed until the battery current reading
re-appears. Release the button.
Now repeat the process to store the new setting.
Hold down the select button
(left arrow) until ‘calibrating . . . ‘
appears; keep the button pressed until the battery current reading
re-appears.
The current reading should now be correct.
No 12 volt output
No 230V supply.
Check all above.
from PSU
Charger not switched on.
Switch charger switch on (i) position, switch will illuminate.
Battery not connected and
Install charged battery as per 3.7.
/ or charged.
Power switch on control
Turn power on at control panel.
panel not switched to ON.
Battery flat/Battery fuse blown.
Recharge battery, check fuses, check charging voltage is present at
battery.
Fuse blown.
Check all fuses are intact and the correct value fuse is installed as
per fuse table.
Equipment switched off/
Check equipment is switched on and connected to the 12V supply.
unplugged.
PSU overheated/auto
Reduce load on system. Allow PSU to cool down. PSU will
shutdown operated.
automatically restart when cool. See 3.2.
Other fault.
Contact your Dealer.
Pump not working
Fuse blown.
Replace fuse.
Pump turned off.
Turn pump on by pressing the pump button at the EC325 control
panel (tap symbol).
Setting incorrect.
Both the internal and external pump feeds are controlled from the
EC325 control panel. To alter the setting of the pump switch (tap
button) see section 4.3.
Ensure the setting matches your desired requirement.
Summary of Contents for lancashire ek
Page 2: ...DATA RECORD ...
Page 10: ...2 4 MOTORHOME CODE ...
Page 16: ...5 2 ARRIVAL AT SITE ...
Page 70: ...7 46 CONNECTION OF SERVICES 12V 230V WIRING DIAGRAM ...
Page 104: ...9 30 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT LANCASHIRE EK ES ...
Page 105: ...9 31 FITTED EQUIPMENT ARRANGEMENT OF EQUIPMENT LANCASHIRE EL ...
Page 110: ...9 36 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE EK ...
Page 111: ...9 37 FITTED EQUIPMENT SINGLE BED ASSEMBLY LANCASHIRE EK ...
Page 112: ...9 38 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE EK ...
Page 113: ...9 39 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE ES ...
Page 114: ...9 40 FITTED EQUIPMENT BENCH SEAT SETTEE ASSEMBLY LANCASHIRE ES ...
Page 115: ...9 41 FITTED EQUIPMENT SINGLE BED ASSEMBLY LANCASHIRE ES ...
Page 116: ...9 42 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE ES ...
Page 117: ...9 43 FITTED EQUIPMENT OVERCAB BED LANCASHIRE ES ...
Page 118: ...9 44 FITTED EQUIPMENT NORMAL SEATING ASSEMBLY LANCASHIRE EL ...
Page 119: ...9 45 FITTED EQUIPMENT DOUBLE BED ASSEMBLY LANCASHIRE EL ...
Page 132: ...11 2 USEFUL INFORMATION Superior craftsmanship within your reach at a dealer near you ...
Page 142: ...12 10 SERVICE DETAILS ...
Page 144: ...13 2 NOTES Designed and Printed by Preset Graphics Tel 01332 205136 HB1096 MY 2011 Ref 21234 ...