CHARGING CABLE VDROP™ TEST
Connect the small leads to
the battery bank - the red on
the positive main and the
black on the negative main
and not to an individual
battery. The added small
external leads will check the
cables before the alternator
is tested. This is the
individual VDrop Test
This same test and hookup can be
run individually by selecting VDrop
Menu
…and then Charging Cables.
ALTERNATOR
HOOKUP
Red to Positive
Black to Ground
BATTERY
HOOKUP
Black Clamp at Negative Main
Red Clamp at Positive Main
>CHARGING CABLES
STR MAIN CABLES
MAG. CIRCUIT
LIFEGATE VDORP
PM TEST
BATTERY TEST
BATTERY BANK
>VDROP MENU
>CONNECT SMALL
LEADS TO THE
BATTERY
'Y' TO BEGIN
Connect the large leads to
the alternator pos. on output
terminal and neg. on case.
PRINTING TEST RESULTS
Point the BCT-200J in the direction of the optional PR-15 printer with the printer’s
IR receiver pointed in the direction of the BCT-200J. Press (Print). You should
be within 15 ft. of the printer. Wait for the screen to clear before moving the BCT-
200J. It takes a moment to send all the test data. The BCT-200J also operates
the AC-14 printer installed in Auto Meter’s XTC-160 tester/charger or BVA-2100
heavy duty tester/analyzer.
For battery, starter, and alternator tests
a unique warranty code is generated
and printed at the bottom of the
printout. This code is used for data and
warranty verification.
Example warranty code:
WARRANTY CODE
2BC0813280B012H12
Make sure the Infrared Printer is
properly set up.
After a test is made with the BCT-
200J make sure the results are
displayed on the LCD.
Point the BCT-200J in the direction
of the Infrared Printer (within 15 ft.)
Press the <Print> key and the test
results will be printed.
Depending upon the test made the
printer will sometimes yield more
information than the LCD.
Wait until the printer stops printing
before you press the BCT-200J
print key again.
Multiple Test Printing:
Pressing the print button
repeatedly (up to six times) will
automatically print the test in
review and the previous tests.