SAFETY
n
Carefully read all operating instructions
before operating the BCT-200J
n
Wear eye protection when working on
batteries.
n
Be sure each test is complete before
removing load clamps to prevent arcing
and potential explosion from battery gases.
Never remove load clamps while testing.
Keep sparks, flames or cigarettes away from
battery.
n
Keep hair, hands, and clothing as well as
tester leads and cords away from moving
blades and belt.
n
Provide adequate ventilation to remove exhaust.
n
In extremely cold temperatures check for frozen
electrolyte fluid or swelled case before applying load. Do not attempt to Load Test or
charge a battery under 20
o
F. (-7
o
C.). Allow the battery to warm to room temperature
before testing or charging.
n
Warning!
BCT-200J can only be attached to a Delco Remy Bench Tester and used
in prescribed manner. It should never be attached to any other tester or charging unit.
Damage may result.
CAUSE OF BATTERY FAILURE
n
Incorrect Application:
Wrong size battery may have inadequate cold cranking rating
for original vehicle specifications.
n
Incorrect Installation:
Loose battery hold-downs cause excessive vibration, which
can result in damage to the plates.
n
Improper Maintenance:
Low electrolytic fluid and corrosion on battery connections
can greatly reduce battery life and effect battery performance.
n
Internal Connections:
Make sure internal connections of entire charging system
meet proper specifications.
n
Age of Battery:
If the date code on the battery is old, test failure may indicate the
need of replacement.
n
Overcharging:
Overcharging caused by a high voltage regulator setting or incorrect
battery charging can cause excessive gas, heat and water loss.
n
Undercharging:
Undercharging caused by a faulty charging system or low voltage
regulator setting can cause lead sulfate to gradually build up and crystallize on the
plates, greatly reducing the battery’s capacity and ability to be recharged.
n
Cycling:
Excessive drain on battery when alternator is not operating.
1 YEAR FROM DATE OF PURCHASE CABLES 90 DAYS
The manufacturer warrants to the consumer that this product will be free from defects in
material or workmanship for a period of one (1) year from the date of original purchase
(90 Days for cables).
Products that fail within this 1 year warranty period will be repaired or replaced at the
manufacturer's option to the consumer when determined by the manufacturer that the product
failed due to defects in material or workmanship. This warranty is limited to the repair or
replacement of parts the necessary labor by the manufacturer to effect the repair or replacement
of the product. In no event shall the manufacturer be responsible for special, incidental or
consequential damages or costs incurred due to the failure of this product.
Improper use, accident, water damage, abuse, unauthorized repairs or alterations voids this
warranty. The manufacturer disclaims any liability or consequential damages due to breach of
any written or implied warranty on its test equipment.
WARRANTY AND SERVICE INFORMATION
Warranty claims to the manufacturer's service department must be transportation prepaid
accompanied with dated proof of purchase. This warranty applies only to the original purchaser
is non-transferable. Shipper damage incurred during return shipments is not covered under this
warranty. It is the responsibility of the shipper (the customer returning the Test Equipment)
to package the tester properly to prevent any damage during return shipment. Repair costs for
such damages will be charged back to shipper (customer returning the Test Equipment). Protect
the product by shipping in the original carton. Add plenty of over-pack cushioning such as
crumpled up newspaper.