75
Rising Rate
– the rate at which the signal level rises
Falling Rate
– the rate at which the signal level falls
Rise Time
– the time the signal takes to rise from the lower threshold to the
upper threshold
Fall Time
– the time the signal takes to fall from the upper threshold to the
lower threshold
X@Max
– the corresponding value of X axis when the amplitude is the
maximum
X@Min
– the corresponding value of X axis when the amplitude is the
minimum
Positive Acreage
– the waveform acreage measured above the zero
baseline
Negative Acreage
– the waveform acreage measured below the zero
baseline
Full Acreage
– the positive acreage plus negative acreage
Top Value
– 90% of the waveform maximum value
Bottom Value
– 10% of the waveform minimum value
Positive Overshoot
– the ratio of the difference between the maximum value
and the top value and the amplitude
Negative Overshoot
– the ratio of the difference between the bottom value
and the minimum value and the amplitude
Positive Pre-shoot
– the ratio of the difference between the bottom value
and the minimum value and the amplitude
Negative Pre-shoot
–the ratio of the difference between the maximum value
and the top value and the amplitude
NOTE
When connecting via Wi-Fi
,
it only supports Maximum, Minimum, Peak To Peak,
Amplitude, Period, Frequency, Positive Duty Ratio, Negative Duty Ratio, Positive
Pulse Width, Negative Pulse Width, AC RMS, True RMS, DC Average, X@Max,
X@Min, Top Value and Bottom Value.
In the
Spectrum View
, the available measurements are as follows.