97
The X-axis and Y-axis can be zoomed using your fingertips. The waveform can be
zoomed during or after capturing the signal.
Measurement Rulers
In the coordinate grid, there are two kinds of
measurement rulers
, which allow the
voltage and time duration of a waveform to be measured precisely. They are useful
when determining signal characteristics such as amplitude at specific points, the
cycle time (duration) and frequency.
The vertical
Time Ruler
- Tap the
Ruler Activator
in the bottom left corner of the
grid and drag it across the screen to the desired position. A
Time Ruler
is
generated.
The horizontal
Y-axis
Ruler
-
The
Ruler
can be generated in the similar way by
tapping the
Ruler Activator
in the upper right corner and dragging it downwards.
NOTE
The horizontal Y-axis ruler varies according to the settings of the voltage, current,
frequency, duty cycle, etc.
When Measurement Rulers are generated, a
Ruler Table
showing time and voltage
values for the corresponding channels will be displayed. The
Delta
icon refers to the
absolute difference between the values of the rulers, which can be locked by
tapping the
Lock
icon. Tap the
X
button in the upper right corner of the ruler table to
delete all rulers.
Figure 1-10
Sample Measurement Rulers Screen