93
Figure 11-15
The screen will display as below, which means the replaced battery is
being entered in the DDE/DME.
Figure 11-16
When the replaced battery has been successfully registered in the
engine electronics, press the
OK
button to end the service function.
If the replaced battery has a different type from the original one, select
[3]
and press the
OK
button to continue.
Refer to the steps described for registering the replaced battery with
higher/lower capacity.
Close-circuit Current
The close-circuit current should always be measured if increased current
consumption is suspected. Battery will discharge at a relatively fast rate even
current consumption rates slightly above the normal.
Close-circuit Current Monitoring Evaluation
1. Use the
UP/DOWN
scroll button to select
Close-circuit current
option
from the Power supply (Battery) menu and press the
OK
button.
2. Select
Evaluate close-circuit current
monitoring option and press the
OK
button to display the last 24 close-circuit current values.
Register battery replacement
Enter 6-digit supplier number as
described.
Finish Show Esc
000000
Register battery replacement
The battery replacement is being
entered in the engine electronics
(DDE or DME)
Please wait!