Installation and operation manual
IM-S2-UX-EN-V1.4
27
Grid ON/OFF
Press UP/DOWN keys to cycle through grid ON/OFF options
Press ENTER key to save
Press ESC key to return
Clear Energy
Reset the inverters total kWh output to zero.
Using this function without previous approval from Autarco
will void any existing kWh Guarantees.
New Password
Change the password to enter Advanced Info and Advanced Settings.
Enter the current password before setting a new password. Press the
DOWN key to move the cursor, Press the UP key to change the digit. Press
the ENTER key to execute the setting. Press the ESC key to return to the
previous menu.
Power Control
Inverter output active power and reactive power control can be set
through this menu if the grid is unbalanced:
1.
Set output power
2.
Set reactive power
3.
Out_P with restore
4.
Rea_P with restore
5.
Select PF curve
Calibrate Energy
Maintenance or replacement could clear or cause a different value for
total energy. Use this function to allow user to revise the value of total
energy to the same value as before.
Press the DOWN key to move the cursor, Press the UP key to revise the
value. Press the ENTER key to execute the setting. Press the ESC key to
return to the previous menu.
Special Settings
Special settings can switch off functions temporarily for testing purposes.
These tests should only be done by qualified Autarco personnel or trained
installers when requested to do so. Submenu includes:
1.
Grid Filter Set
2.
Relay_Protect Set
3.
ILeak_Protect Set
4.
GROUND_Protect Set
5.
GRID INTF.02 Set
6.
MPPT Parallel Mode
7.
Cnst. Voltage Mode
8.
L/FRT Set
9.
IgZero_COMP. Set
10.
PI Set
11.
IgADCheckPRO Set
12.
NoSmallPulse Set
13.