Turning ON/OFF
ź
ź
In order to
turn on
the device press
button and keep it
pressed for 3 sec.
In order to
turn off
the device:
- press
button and keep it pressed for 3 sec .
- or press
, button and the display will show a pick list.
Use controller for “up” and “down” selection
and
select
TURN OFF
option, then confirm the choice by
pressing
.
[Pow ]
[Po]
[kon]
[ko]
[Po ]
Description of connection terminals
Connection terminals are located under the button cover. To remove the cover, unscrew
two fixing screws located at the bottom side of the device.
L
N
E
COM NO
NC
L
N
E
L
N1
E
N2
L
N
E
N1
L
N2
L
N3
L
N4
L
N5
L
N6
L
N7
L
N8
L
E
N
L
1
2
3
4
5
6
7
8
230VAC
ATTENTION: All connections should be made with disconnected power
supply
!
Central
heating pump
Power supply
230V 50HZ
Terminal for
hot utility water
circulation pump
Potential-free
relay contacts
Terminals for
heating zones (head)
OK
AURATON
8000
Cancel
Delete wireless
devices
< English >
Turn off
Pairing and deleting wireless temperature
controllers shown on the example of
AURATON 200 and AURATON 2030 RTH (clock)
ź
a
ź
set temperature
ź
Each zone may be paired with a wireless thermostat (and/or thermometer) and
wireless window handle operating in LMS standard
Thermostat transmits the following 3 parameters to the paired channel of A-8000:
- current temperature
- set hysteresis
-
When after pairing the thermostat, the user adds T-2 thermometer to the paired
channel , the actual temperature will be read from T-2 thermometer, whereas only the
set temperature will be read from the thermostat. This allows the user to control the
temperature in a room other than the room, where thermostat is installed.
NOTE:
In the configuration with thermostat and T-2 thermometer it is important to keep
the correct order of pairing the devices. Always pair the thermostat first and then
T-2 thermometer. Re-pairing thermostat will delete T2 thermometer from the
channel. The window handle should be paired as the last element.
NOTE:
If a given zone is paired only with T-2 thermometer, then AURATON 8000 will
maintain default (factory set) temperature of 20°C in the room where this
thermometer is installed.
NOTE:
Manufacturer suggests to log-in at least 1 AURATON regulator with a clock (e.g.
AURATON 2030 RTH in wireless version), to make AUTO24 function operate
accurately.
Mounting the controller
The controller may be mounted on a wall using two fixing screws (rawplugs with screws are
provided with the controller).
Cables of the controller shall be fixed to the wall with brackets.
NOTE:
Do not mount the controller on metal boxes. It may cause interferences in proper
operation of the device.
4
5
NOTE:
the “pick list” enables user to set the language of
displayed messages.