In case of any problems with communication due to e.g. excessive distance of
Auraton 8000
from the regulators a repeater (signal amplifier) may be used.
ź
ź
ź
ź
ź
ź
Do not mount the controller in a metal cabinet, as it will reduce (shield) its radio signal.
It is assumed that a signal level below 20% requires the use of a repeater (LMS signal
amplifier).
In some locations LMS signal propagation form wireless devices may be very difficult. In
such cases a repeater (amplifier) installed between the transmitter (device) and
Auraton 8000
of will ensure correct proper operation of the system.
In extreme cases (large distances, metal barriers, more floors), it may be necessary to
use more than one repeater to ensure the correct transmission of the signal.
More information about repeaters may be found on the manufacturer's website
WWW.AURATON.PL
All connections shall be always made with disconnected power supply.
It is recommended to commission the installation of the controller to a specialized
company.
15
Comments
Description of AUTO 24 function
NOTE:
The manufacturer suggests to log in (pair) at least one 1
AURATON
regulator,
equipped with a clock (
e.g. AURATON 2030 RTH
), to make
AUTO 24
function
operate precisely.
AUTO 24
function enables the user to control valves (heating), central heating pump and
the relay which controls the furnace when communication with the controller fails due to
discharged batteries or controller malfunction.
In this case
AURATON 8000
runs the same heating schedule for a given zone (the one with
lost communication) as for the last 24 hours stored in the controller memory.
Description of voltage output of central heating pump
The central heating pump is turned on
, when any of heating zones is activated.
The central heating pump is turned off
, when no heating zone is activate.
A special anti-seizing algorithm overrides any other control settings of the heating pump. It
activates the pump for 15 seconds in the following cases:
After the controller detects the pump for the first time or each time after turning on
the power supply and the relay.
Every 14 days after turning the pump is turned off, provided that A-8000 is turned
on.
ź
ź
Description of potential-free output
for controlling central heating furnace
Controlling the relay (e.g. central heating furnace)
Activating a regulation head in any zone results in activating the relay.
The relay is turned off, when the heating is turned off in all zones.
This function operates simultaneously to the control of the output of central heating pump.
RESETTING the controller
In order to reset the controller to its default settings, proceed as
follows:
1. Press ON/OFF button
(a single acoustic signal will be
emitted). The display will show a pick list.
2. Use controller
(up & down) to select option
Delete
wireless devices
, and then press
button and keep it
pressed for 5 seconds.
3. Correctly performed RESET operation will be confirmed by
acoustic signal.
[pow]
[kon]
[KO]
"
"
OK
NOTE: RESET of the controller results in deleting all paired devices and user’s settings
from the controller’s memory.
AURATON
8000
Cancel
Delete wireless
devices
< English >
Turn off
Additional information
ź
ź
Left side of the controller
is the place where antenna socket is installed (used in case of
radio communication problems ) and mini USB slot (for servicing purposes).
Right side of the controller
is the place where fuse socket is located (4A, time-delay
fuse).