background image

In  order  to  delete  (log-out)  a  device  from  the  selected  zone,  perform  the  following 
procedures:

1.

If the zone with a paired LMS device is known, press the button of this zone and keep it 
pressed longer than 5sec. After 3 seconds a single acoustic signal is emitted – do not 
release the button and after the next 2seconds a double acoustic signal is emitted – the 
zone automatically enters deleting mode  (the display will show the antenna symbol).
After one zone is entered into deleting mode, other zones may enter this mode by short 
pressing the respective zone button. It enables the user to delete a device from more 
than one zone.

2.

Then, in order to delete a LMS wireless devices (e.g. temperature regulator) from the 
zone,  activate  “deleting”  mode  in  LMS  wireless  device  (detailed  instructions  on 
activating "deleting" mode in a selected device is in its manual).

3.

If the LED for selected zone stops blinking, it means that all LMS devices in that zone have 
been correctly deleted.
When a LED of any zone continues to blink after deleting process, it means that the 
controller waits for deleting other LMS devices.

NOTE:

    Deleting process in selected zone turns off automatically after 60s.

Deleting wireless devices (LMS) from a zone

In  order  to  delete  all  LMS  from 

AURATON  8000

,  proceed  as 

follows:

1. Press ON/OFF button 

 (single acoustic signal is emitted). 

The display will show a pick list.

2. Use  the  controller 

(up  &  down)  to  select  “

Delete 

wireless devices

”, and the confirm it by pressing 

3. Use the controller

  (up & down) to select the device to be 

deleted  from the pick list. Confirm  the selection  by pressing

or 3 seconds.

[pow]

[kon]

[KO]

 [KO]

[ko] 

  

 f

Deleting wireless devices (LMS) using a list

OK

OK

NOTE:

After  selecting  a  device  from  the  list,  LEDs  are 
activated  next  to  the  zone  to  which  the  device  is 
paired.

AURATON

8000

Cancel

Delete wireless 
devices 

<    English                         >

Turn off

Pairing wireless devices to a zone

In order to pair wireless temperature sensors, thermostats or LMS window handles with the 
selected zone perform the following procedures:

1. Press the button of a selected zone 

 for 3s, wait for

a single acoustic signal and then release the button. Entering the 
zone into pairing mode is signalled by pulsating LED of this zone 
(every 0.5s) and by displayed antenna symbol on the display.

After a zone enters the pairing mode, other zones may be also 

entered  into  this  mode  by  briefly  pressing  the  button  of  any 
other  zone.  This  enables  the  user  to  simultaneously  pair  the 
same thermostat and/or thermometer to more than one zone.

2. Then, in order to pair a LMS wireless device (e.g. temperature 

regulator) to the zone, run "pairing" mode in the selected LMS 
wireless  device 

(detailed  instructions  on  activating  "pairing" 

mode in a selected device is in its manual)

.

3. Correct  pairing  of  a  LMS  device  is  confirmed  by  a  1-second 

acoustic signal.

4. When  the  button  of  the  zone  in  "pairing"  mode  is  shortly 

pressed, then the "pairing" mode is turned off. 

5.  When the „pairing" mode is turned off in all zones, A8000 enters 

the mode of normal operation.

NOTE:

The "pairing" mode is automatically switched off 60 seconds after the last zone is 
entered  or  after  correctly  completed  pairing  of  a  LMS  device  or  after  a  short 
press of the selected zone button.

NOTE:

One zone may be paired only with one thermostat. Remember that, after pairing a 
zone with a new thermostat, the thermostat paired previously with this zone will 
be deleted.

NOTE:

If the zone was paired with a thermostat and then with a thermometer, then the 

zone  will  log-in  both  devices.  The  set  temperature  will  be  read  from  the 
thermostat, and the actual temperature from the thermometer. One zone may be 
paired only with one thermostat and/or thermometer.

)

[1 ]...[8 ] 

6

7

- temperature controller symbol 

- thermometer symbol

- window handle symbol

ID:  0243DB60

ID:  01313094

ID:  01C9D186

ID:  AAFC9022

Summary of Contents for AURATON 8000

Page 1: ...Owner s manual www auraton pl 8000 AURATON 8000 ...

Page 2: ...ystem It provides information about the window position to the controller The handle recognizes 4 window positions open closed pivotedandtrickle ventposition microventilation The handle transmits information to AURATON 8000 controller which activates the relay e g switching off a heater after opening the window or reducing temperature by 3 C when the window is pivoted inordertosaveenergy AURATON80...

Page 3: ...ntral heating pump and a potential free outputthatmaybeusedforcontrollingcentralheatingfurnace AURATON 8000 communicates with wireless transmitters using modern transmission protocolLMS Description of AURATON 8000 Button of hot water circulation pump Multi functional controller left right up down OK button OK LCD display ON OFF button Button cover Buttons of heating zones 1 8 LED signalling ON OFF...

Page 4: ...dbemadewithdisconnectedpower supply Central heating pump Power supply 230V 50HZ Terminal for hot utility water circulation pump Potential free relay contacts Terminals for heating zones head P c A ź ź ź N N N Mounting the controller The controller may be mounted on a wall using two fixing screws rawplugs with screws are providedwiththecontroller Cablesofthecontrollershallbefixedtothewallwithbracke...

Page 5: ... user adds T 2 thermometer to the paired channel the actual temperature will be read from T 2 thermometer whereas only the set temperature will be read from the thermostat This allows the user to control the temperatureinaroomotherthantheroom wherethermostatisinstalled NOTE In the configuration with thermostat and T 2 thermometer it is important to keep the correct order of pairing the devices Alw...

Page 6: ...tructions on activating pairing modeinaselecteddeviceisinitsmanual 3 Correct pairing of a LMS device is confirmed by a 1 second acousticsignal 4 When the button of the zone in pairing mode is shortly pressed thenthe pairing modeisturnedoff 5 Whenthe pairing modeisturnedoffinallzones A8000enters themodeofnormaloperation NOTE The pairing mode is automatically switched off 60 seconds after the last z...

Page 7: ...D forselectedzonestopsblinking itmeansthatallLMSdevicesinthatzonehave beencorrectlydeleted When a LED of any zone continues to blink after deleting process it means that the controllerwaitsfordeletingotherLMSdevices NOTE Deletingprocessinselectedzoneturnsoffautomaticallyafter60s Deleting wireless devices LMS from a zone In order to delete all LMS from AURATON 8000 proceed as follows 1 PressON OFFb...

Page 8: ...elayturnedoff LEDactiveat10 Central heating pump detected but turned off relayturnedoff LEDactiveat100 Centralheatingactive relayturnedon LEDinactive The heating zone has no LMS device paired no regulation head is connected to the connection witharespectivenumber LEDactiveat10 The heating zone has a LMS device paired and a regulationheadisconnected heatingisturnedoff LEDactiveat100 The heating zon...

Page 9: ...ensure correct operation weekly programming it is necessary to pair at least one regulator with a clock e g AURATON 2025 RTH or AURATON2030RTH When only 24 h regulators without a clock e g AURATON 200 are paired then the pump operates only in interval mode operating time and break time may be programmed Hot water circuit MO F TU WE TH R SA SU 5 min 10 min Controlling the circulation pump in hot ut...

Page 10: ... of the whole week settings ofonedayoftheweekmaybecopiedtoanother e g the time line form Monday bay be copied for Tuesday Wednesday ThursdayandFriday Tocopythetimelineformadayoftheweek proceedasfollows 1 Usecontroller up down toselectadayoftheweek tobe copied e g Monday andconfirmitbypressing button 2 After that changes may be introduced to the time line but they are not necessary Press again butt...

Page 11: ...sing button 4 Then use controller left right to set the stoppage time and confirm it by pressing Now it is possible to set the stoppage time of the pump in minutes use controller up down Afterthisvalueisset confirmitbypressing 5 Now operation parameters of the circulation pump in the selected hour are set active rectangle KO KO KO KO KO troj KO KO KO a troj b button utton OK OK OK OK Hot water cir...

Page 12: ...H At least one 1 temperature regulator equipped with a clock must be paired with the device If not this information will not be displayed Informs about pump operational status Pump turned on Pump turned off Empty field indicates that no device from this zone is paired with the controller Indicates activated relay heating of the zone 23 0 C 21 0 C Temperature in the zone Set temperature If temperat...

Page 13: ...tivated relay heating of the zone Temperature in the zone Set temperature If temperature in the zone drops below the set value then heating of the zone will be activated Signal strength received from paired device Battery status of paired device Status of other devices paired with the zone here a wireless window handle AURATON H 1 Hysteresis History of relay operation for the last 24 hours graph 1...

Page 14: ...central heating pump Thecentralheatingpumpisturnedon whenanyofheatingzonesisactivated Thecentralheatingpumpisturnedoff whennoheatingzoneisactivate A special anti seizing algorithm overrides any other control settings of the heating pump It activatesthepumpfor15secondsinthefollowingcases After the controller detects the pump for the first time or each time after turning on thepowersupplyandtherelay...

Page 15: ...ionsshallbealwaysmadewithdisconnectedpowersupply It is recommended to commission the installation of the controller to a specialized company 15 Comments RESETTING the controller In order to reset the controller to its default settings proceed as follows 1 Press ON OFF button a single acoustic signal will be emitted Thedisplaywillshowapicklist 2 Use controller up down to select option Delete wirele...

Page 16: ...and acoustic signal Automatic detection of connected heads central heating pump and circulation pump 8 30 W per zone controlling heads 230V up to 6 AURATON regulators heating pump 230V Disposal The devices are marked with a crossed wheeled bin In accordance with European Directive 2002 96 EC and the Act on Waste Electrical and Electronic Equipment this marking indicates that the device after compl...

Reviews: