background image

LED blinks three times per 5sec.

The heating zone has a regulation head connected 
and a LMS device is paired, but the zone does not 
receive  correct  signals  from  LMS  device  –

  The 

zone  implements  the  heating  algorithm  in 
emergency mode (AUTO 24)

LED blinks slowly (every 0.5s.)

The heating zone is in pairing mode

LED blinks quickly

The heating zone is in deleting mode

Description  of voltage output  of the circulation pump in
hot utility water circuit.
Programming the operation the circulation pump in hot 
utility water circuit – example of AURATON 2030 RTH.

NOTE

:

In order to ensure correct operation (weekly programming), it is necessary to pair 
at  least  one  regulator  with  a  clock  e.g. 

AURATON  2025  RTH

  or 

AURATON 2030 RTH

When only 24 h regulators without a clock (e.g. 

AURATON 200

) are paired, then 

the pump operates only in interval mode (operating time and break time may be 
programmed).

Hot water circuit
MO     

F

TU
WE
TH

R

SA
SU

5[min]

10[min]

Controlling the circulation pump in hot utility water circuit

The  controller  may  be  programmed  with  a  weekly  operation 
schedule  of  the  circulation  pump.  In  order  to  program  the 
operation pump, follow the procedure:

1. Press the circulation pump button 

, to enter "

Hot water 

circuit

" mode.

The display will show a weekly schedule of pump operation. Each 
day of the week is presented on the timeline.

[wiat]

 

ź

ź

Activating the regulator head in any heating zone of 

AURATON 8000

 results in activating 

the relay.

The relay is turned off when heating in all zones of  

AURATON 8000 

is turned off.

Controlling the relay

Signalling controller operation

The controller signals its operation by LEDs, LCD and acoustic signals.

Power supply (ON/OFF) LED:

LED signalling operation of the circulation pump and relay:

LEDs of heating zones :

                                    

ź

ź

ź

ON/OFF LED inactive:

The controller is switched OFF

ON/OFF LED is continuously on:

The controller is in normal operation mode 

LED inactive:

No central heating pump – relay turned off

LED active at 10%:

Central  heating  pump  detected,  but  turned  off  – 
relay turned off 

LED active at 100%:

Central heating active – relay turned on

LED inactive:

The  heating  zone  has  no  LMS  device  paired;  no 
regulation  head  is  connected  to  the  connection 
with a respective number

LED active at 10%:

The  heating  zone  has  a  LMS  device  paired  and  a 
regulation head is connected – heating is turned off

LED active at 100%:

The  heating  zone  has  a  LMS  device  paired  and  a 
regulation head is connected – heating is turned on

LED blinks once per 5 sec.

Regulation head is connected, but no LMS device is 
paired – 

The zone is not ready to implement the 

heating algorithm 

LED blinks twice per 5sec.

LMS  device  is  paired,  but  no  regulation  head  is 
connected – 

The zone is not ready to implement 

the heating algorithm

8

9

Summary of Contents for AURATON 8000

Page 1: ...Owner s manual www auraton pl 8000 AURATON 8000 ...

Page 2: ...ystem It provides information about the window position to the controller The handle recognizes 4 window positions open closed pivotedandtrickle ventposition microventilation The handle transmits information to AURATON 8000 controller which activates the relay e g switching off a heater after opening the window or reducing temperature by 3 C when the window is pivoted inordertosaveenergy AURATON80...

Page 3: ...ntral heating pump and a potential free outputthatmaybeusedforcontrollingcentralheatingfurnace AURATON 8000 communicates with wireless transmitters using modern transmission protocolLMS Description of AURATON 8000 Button of hot water circulation pump Multi functional controller left right up down OK button OK LCD display ON OFF button Button cover Buttons of heating zones 1 8 LED signalling ON OFF...

Page 4: ...dbemadewithdisconnectedpower supply Central heating pump Power supply 230V 50HZ Terminal for hot utility water circulation pump Potential free relay contacts Terminals for heating zones head P c A ź ź ź N N N Mounting the controller The controller may be mounted on a wall using two fixing screws rawplugs with screws are providedwiththecontroller Cablesofthecontrollershallbefixedtothewallwithbracke...

Page 5: ... user adds T 2 thermometer to the paired channel the actual temperature will be read from T 2 thermometer whereas only the set temperature will be read from the thermostat This allows the user to control the temperatureinaroomotherthantheroom wherethermostatisinstalled NOTE In the configuration with thermostat and T 2 thermometer it is important to keep the correct order of pairing the devices Alw...

Page 6: ...tructions on activating pairing modeinaselecteddeviceisinitsmanual 3 Correct pairing of a LMS device is confirmed by a 1 second acousticsignal 4 When the button of the zone in pairing mode is shortly pressed thenthe pairing modeisturnedoff 5 Whenthe pairing modeisturnedoffinallzones A8000enters themodeofnormaloperation NOTE The pairing mode is automatically switched off 60 seconds after the last z...

Page 7: ...D forselectedzonestopsblinking itmeansthatallLMSdevicesinthatzonehave beencorrectlydeleted When a LED of any zone continues to blink after deleting process it means that the controllerwaitsfordeletingotherLMSdevices NOTE Deletingprocessinselectedzoneturnsoffautomaticallyafter60s Deleting wireless devices LMS from a zone In order to delete all LMS from AURATON 8000 proceed as follows 1 PressON OFFb...

Page 8: ...elayturnedoff LEDactiveat10 Central heating pump detected but turned off relayturnedoff LEDactiveat100 Centralheatingactive relayturnedon LEDinactive The heating zone has no LMS device paired no regulation head is connected to the connection witharespectivenumber LEDactiveat10 The heating zone has a LMS device paired and a regulationheadisconnected heatingisturnedoff LEDactiveat100 The heating zon...

Page 9: ...ensure correct operation weekly programming it is necessary to pair at least one regulator with a clock e g AURATON 2025 RTH or AURATON2030RTH When only 24 h regulators without a clock e g AURATON 200 are paired then the pump operates only in interval mode operating time and break time may be programmed Hot water circuit MO F TU WE TH R SA SU 5 min 10 min Controlling the circulation pump in hot ut...

Page 10: ... of the whole week settings ofonedayoftheweekmaybecopiedtoanother e g the time line form Monday bay be copied for Tuesday Wednesday ThursdayandFriday Tocopythetimelineformadayoftheweek proceedasfollows 1 Usecontroller up down toselectadayoftheweek tobe copied e g Monday andconfirmitbypressing button 2 After that changes may be introduced to the time line but they are not necessary Press again butt...

Page 11: ...sing button 4 Then use controller left right to set the stoppage time and confirm it by pressing Now it is possible to set the stoppage time of the pump in minutes use controller up down Afterthisvalueisset confirmitbypressing 5 Now operation parameters of the circulation pump in the selected hour are set active rectangle KO KO KO KO KO troj KO KO KO a troj b button utton OK OK OK OK Hot water cir...

Page 12: ...H At least one 1 temperature regulator equipped with a clock must be paired with the device If not this information will not be displayed Informs about pump operational status Pump turned on Pump turned off Empty field indicates that no device from this zone is paired with the controller Indicates activated relay heating of the zone 23 0 C 21 0 C Temperature in the zone Set temperature If temperat...

Page 13: ...tivated relay heating of the zone Temperature in the zone Set temperature If temperature in the zone drops below the set value then heating of the zone will be activated Signal strength received from paired device Battery status of paired device Status of other devices paired with the zone here a wireless window handle AURATON H 1 Hysteresis History of relay operation for the last 24 hours graph 1...

Page 14: ...central heating pump Thecentralheatingpumpisturnedon whenanyofheatingzonesisactivated Thecentralheatingpumpisturnedoff whennoheatingzoneisactivate A special anti seizing algorithm overrides any other control settings of the heating pump It activatesthepumpfor15secondsinthefollowingcases After the controller detects the pump for the first time or each time after turning on thepowersupplyandtherelay...

Page 15: ...ionsshallbealwaysmadewithdisconnectedpowersupply It is recommended to commission the installation of the controller to a specialized company 15 Comments RESETTING the controller In order to reset the controller to its default settings proceed as follows 1 Press ON OFF button a single acoustic signal will be emitted Thedisplaywillshowapicklist 2 Use controller up down to select option Delete wirele...

Page 16: ...and acoustic signal Automatic detection of connected heads central heating pump and circulation pump 8 30 W per zone controlling heads 230V up to 6 AURATON regulators heating pump 230V Disposal The devices are marked with a crossed wheeled bin In accordance with European Directive 2002 96 EC and the Act on Waste Electrical and Electronic Equipment this marking indicates that the device after compl...

Reviews: