background image

Rev. 02/11 

AMMF16R-1

 

 

When using this misting fan follow basic safety precautions including the following:

 

WARNING:

 

To reduce the risk of fire, electric shock, or injury:

 

1.    Make sure that the power source complies with the electrical requirements of the misting fan. 

2.    Do not use this misting fan with any solid state speed control device.         

3.    Do not expose to rain. Store indoors. 

4.    Do not use this misting fan with a damaged filter or without a filter installed. 

5.    To reduce the risk of personal injury, the misting fan should not be used as a toy or placed where         

children can reach it.   

6.    Close supervision is necessary when any appliance is used near children. 

7.    Use this misting fan only as described in this manual.    Any other use may cause electrical shock,     

fire, injury to people or animals. 

 

WARNING:

 DO NOT USE THE MISTING ON-OFF SWITCHES AS A MEANS OF 

DISCONNECTING  POWER  WHEN  INSTALLING  OR  SERVICING  THIS  PRODUCT.   
ALWAYS DISCONNECT THE POWER CORD. 

8.  Disconnect the power cord before moving or performing any maintenance on the misting fan. 

9.   This misting fan shall not be used in potentially dangerous conditions, such as flammable,   

explosive or chemically loaded atmospheres. 

10.  Do not use or store near hazardous materials. 

11.  Completely assemble the misting fan according to these instructions before connecting to the   

power source.   

12.  If the misting fan is not working correctly, has missing parts, has been dropped or damaged or 

dropped in water, call an authorized service center for evaluation, adjustment or repair. 

WARNING:

 

IMPROPER CONNECTION OF THE EQUIPMENT-GROUNDING 

CONDUCTOR CAN RESULT IN A RISK OF ELECTRICAL SHOCK.    CHECK WITH A 
QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO 
WHETHER THE OUTLET IS PROPERLY GROUNDED.    DO NOT MODIFY THE PLUG 
PROVIDED WITH THE MISTING FAN IF IT WILL NOT FIT THE OUTLET; HAVE A 
PROPER OUTLET INSTALLED BY A QUALIFIED ELECTRICIAN. DO NOT USE A 
THREE-PRONG TO TWO-PRONG ADAPTER. IMPROPER CONNECTION MAY CREATE 
A RISK FOR ELECTRICAL SHOCK. 

 

13.    To protect against a risk of fire, electric shock, or injury to persons

  unplug or disconnect the 

appliance from the power supply before cleaning and user-maintenance, such as lubrication.

 

14.    Keep the cord away from heated surfaces. 

15.    To reduce the risk of injury from the misting fan accidentally starting, unplug the power cord   

before replacing the filter. 

16.    Do not leave the misting fan unattended when it is plugged in. Unplug it from the power outlet   

when not in use and before servicing. Turn off the misting fan before unplugging. 

17.    Do not operate the misting fan with a damaged power cord, plug, or if the misting fan is   

damaged in any manner.    Call an authorized service center for evaluation, adjustment or   

repair. 

18.    Do not run cord under carpets. Do not cover cord with throw rugs, runners, or similar   

Summary of Contents for AMMF16R-1

Page 1: ...ESE INSTRUCTIONS CAUTION Before using this product read this manual and follow all safety rules and operating instructions Failure to comply with instructions could result in personal injury and or property damage IMPORTANT For replacement parts or assembly questions call 1 800 320 6478 or go to www auramist net ...

Page 2: ...els on the misting fan before using Safety is a combination of common sense staying alert and knowing how this misting fan works Use this misting fan only as described in this manual To reduce the risk of personal injury or damage to the misting fan use only recommended accessories Understanding Safety Terminology DANGER If safety information is not followed someone will be seriously injured or ki...

Page 3: ...e connecting to the power source 12 If the misting fan is not working correctly has missing parts has been dropped or damaged or dropped in water call an authorized service center for evaluation adjustment or repair WARNING IMPROPER CONNECTION OF THE EQUIPMENT GROUNDING CONDUCTOR CAN RESULT IN A RISK OF ELECTRICAL SHOCK CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO...

Page 4: ...xample bathtub or pool or anything containing an electrical conductive substance 23 When the product is used outdoors use only on GFCI Ground Fault Circuit Interrupter protected receptacles 24 This product must be grounded If it should malfunction or break down grounding provides a path of least resistance for electric current to reduce the risk of electric shock This product is equipped with a co...

Page 5: ...nut screw on motor housing 1 4 Fan blade 1 5 Fan blade nut screw on motor axis 1 6 Power base assembly 1 7 Fan head assembly 1 8 Fan pole assembly 1 9 Fan pole screw 1 10 Screws 3 2 Carton Contents Check packing contents to pack list If anything is missing please call Customer Service at 1 800 320 6478 ...

Page 6: ...mbly fig 4 7 Disassemble the rear fan guard nut and the misting fan blade nut from the misting fan head assembly fig 5 8 Align the rear fan guard holes to the three pins on the motor housing and fasten the rear fan guard to the fan head assembly with the rear fan guard nut figure 6 9 Mount the fan blade to the fan motor shaft fig 7 Make sure the fan blade gap aligns with the pin clip on the motor ...

Page 7: ...LLY PLUGGED INTO THE POWER OUTLET Fan Operation ON OFF Speed control Press the button to Low Medium High or OFF to select fan speed fig 1 Fan Operation Oscillation Control To activate the oscillation function press down the oscillation switch To deactivate stop the oscillation function pull up the oscillation switch The oscillation angle is approximately 65 degrees fig 2 Misting Operation IMPORTAN...

Page 8: ...ng ON OFF control Mist ON 1 Press the rocker switch to the ON position fig 5 2 Turn the ball valve to the ON position fig 6 3 Open the flow control valve until mist is visible then refer to ADJUSTING MIST DENSITY section to get an optimal mist performance fig 7 Mist OFF 1 Turn the ball valve to OFF position fig 8 2 To prevent the accumulation of mineral deposits let the pump run for 2 minutes afte...

Page 9: ...ncreasing the water flow will provide maximum cooling results In humid climates a reduced water flow is recommended CUSTOMER RESPONSIBILITIES Read and follow the maintenance schedule and the maintenance procedures listed in this section WARNING ALLWAYS UNPLUG THE POWER CORD BEFORE MOVING OR SERVICING THE MISTING FAN WARNING DO NOT IMMERSE THE MISTING MIST FAN IN WATER REPLACING FILTERS WARNING ANY...

Page 10: ...st fan in a clean and dry place PROBLEM CAUSE CORRECTION Misting fan not running 1 Power cord is not connected 2 Switch is in the OFF position 1 Connect power cord 2 Switch mist fan on high medium low and positions Unit not misting 1 Water faucet is OFF 2 Ball valve is OFF 3 Misting valve in the CLOSED position 4 Water filter could be clogged 1 Open the water faucet 2 Switch the ball valve to ON p...

Page 11: ...Rev 02 11 AMMF16R 1 11 Exploded View ...

Page 12: ...0 03 water pre filter 1 11 FV9144 70 10 ball valve 1 12 ZF01MF A0 02 base plate assembly 1 13 ZF01MF 30 00 pump Bushings 4 14 WZQB01 00 00 air pump 1 15 ZF01MF 20 00 fan pole assembly 1 16 ZF01MF A0 03 fan head assembly 1 17 ZF01MF 10 03 rear guard 1 18 ZF01MF 10 22 rear grill nut 1 19 ZF01MF 10 02 fan blade 1 20 ZF01MF 10 21 blade nut 1 21 ZF01MF 10 01 front guard 1 22 FV9144 00 03 nozzle housing...

Page 13: ... near you Call the number below to get the nearest service center This warranty does not include the air or water filters which are expendable parts that can wear out from normal use within the warranty period This warranty applies for only 90 days if this product is ever used for commercial or rental purposes auraMIST Inc 5210 Village Parkway Rogers AR 72758 The model number and manufacturing dat...

Reviews: