Rev. 02/11 

AMMF16R-1

 

 

ADJUSTING MIST DENSITY 

CAUTION:

 Do not over tighten and/or loosen the water flow control valve.   

The  misting  function  of  this  fan  is  adjusted  by  turning  the  flow  control  valve  on  the  fan  pole  assembly 

clockwise to decrease mist density or counter-clockwise to increase mist density. It may take a minute for 

misting to start. It is normal for air to come out of the nozzles before water and the mist comes out.

 

To optimize the cooling effectiveness of the system, you can: 

    Operate the unit with a DRY or WET mist, based on your needs. 

    To increase the mist density, turn the mist control valve counter-clockwise (fig.10). 

    To decrease the mist density, turn the mist control valve clockwise (fig.11). 

2. Operating Tips 

For dry climates, increasing the water flow will provide maximum cooling results.    In humid climates, a 

reduced water flow is recommended. 

 

 

 

 

 

 

 

 

 

 

 

CUSTOMER RESPONSIBILITIES 

Read and follow the maintenance schedule and the maintenance procedures listed in this section. 

 

WARNING:

 

ALLWAYS  UNPLUG  THE  POWER  CORD  BEFORE  MOVING  OR 

SERVICING THE MISTING FAN.

 

WARNING:

 

DO NOT IMMERSE THE MISTING MIST FAN IN WATER!   

 

 

REPLACING FILTERS 

 

WARNING:

 

ANY  SERVICING  OF  THIS  UNIT,  EXCEPT  FOR  GENERAL 

MAINTENANCE  DESCRIBED  IN  THIS  SECTION,  SHOULD  BE  PERFORMED  BY  AN 
AUTHORIZED SERVICE REPRESENTATIVE. 

CAUTION:

  The  filters  have  been  designed  to  provide  optimal  system 

performance by catching any debris that may enter the supply lines throughout use.   
Semi  annual  replacement  of  both  the  air  and  water  filters  ensures  the  life  of  your 
system. 

 

 

Remove the filter cover and locate the air and water filters (fig.1).   

 

The filters are connected to the system via “Push-In” connectors for ease of service 

Maintenance   

 

Summary of Contents for AMMF16R-1

Page 1: ...ESE INSTRUCTIONS CAUTION Before using this product read this manual and follow all safety rules and operating instructions Failure to comply with instructions could result in personal injury and or property damage IMPORTANT For replacement parts or assembly questions call 1 800 320 6478 or go to www auramist net ...

Page 2: ...els on the misting fan before using Safety is a combination of common sense staying alert and knowing how this misting fan works Use this misting fan only as described in this manual To reduce the risk of personal injury or damage to the misting fan use only recommended accessories Understanding Safety Terminology DANGER If safety information is not followed someone will be seriously injured or ki...

Page 3: ...e connecting to the power source 12 If the misting fan is not working correctly has missing parts has been dropped or damaged or dropped in water call an authorized service center for evaluation adjustment or repair WARNING IMPROPER CONNECTION OF THE EQUIPMENT GROUNDING CONDUCTOR CAN RESULT IN A RISK OF ELECTRICAL SHOCK CHECK WITH A QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO...

Page 4: ...xample bathtub or pool or anything containing an electrical conductive substance 23 When the product is used outdoors use only on GFCI Ground Fault Circuit Interrupter protected receptacles 24 This product must be grounded If it should malfunction or break down grounding provides a path of least resistance for electric current to reduce the risk of electric shock This product is equipped with a co...

Page 5: ...nut screw on motor housing 1 4 Fan blade 1 5 Fan blade nut screw on motor axis 1 6 Power base assembly 1 7 Fan head assembly 1 8 Fan pole assembly 1 9 Fan pole screw 1 10 Screws 3 2 Carton Contents Check packing contents to pack list If anything is missing please call Customer Service at 1 800 320 6478 ...

Page 6: ...mbly fig 4 7 Disassemble the rear fan guard nut and the misting fan blade nut from the misting fan head assembly fig 5 8 Align the rear fan guard holes to the three pins on the motor housing and fasten the rear fan guard to the fan head assembly with the rear fan guard nut figure 6 9 Mount the fan blade to the fan motor shaft fig 7 Make sure the fan blade gap aligns with the pin clip on the motor ...

Page 7: ...LLY PLUGGED INTO THE POWER OUTLET Fan Operation ON OFF Speed control Press the button to Low Medium High or OFF to select fan speed fig 1 Fan Operation Oscillation Control To activate the oscillation function press down the oscillation switch To deactivate stop the oscillation function pull up the oscillation switch The oscillation angle is approximately 65 degrees fig 2 Misting Operation IMPORTAN...

Page 8: ...ng ON OFF control Mist ON 1 Press the rocker switch to the ON position fig 5 2 Turn the ball valve to the ON position fig 6 3 Open the flow control valve until mist is visible then refer to ADJUSTING MIST DENSITY section to get an optimal mist performance fig 7 Mist OFF 1 Turn the ball valve to OFF position fig 8 2 To prevent the accumulation of mineral deposits let the pump run for 2 minutes afte...

Page 9: ...ncreasing the water flow will provide maximum cooling results In humid climates a reduced water flow is recommended CUSTOMER RESPONSIBILITIES Read and follow the maintenance schedule and the maintenance procedures listed in this section WARNING ALLWAYS UNPLUG THE POWER CORD BEFORE MOVING OR SERVICING THE MISTING FAN WARNING DO NOT IMMERSE THE MISTING MIST FAN IN WATER REPLACING FILTERS WARNING ANY...

Page 10: ...st fan in a clean and dry place PROBLEM CAUSE CORRECTION Misting fan not running 1 Power cord is not connected 2 Switch is in the OFF position 1 Connect power cord 2 Switch mist fan on high medium low and positions Unit not misting 1 Water faucet is OFF 2 Ball valve is OFF 3 Misting valve in the CLOSED position 4 Water filter could be clogged 1 Open the water faucet 2 Switch the ball valve to ON p...

Page 11: ...Rev 02 11 AMMF16R 1 11 Exploded View ...

Page 12: ...0 03 water pre filter 1 11 FV9144 70 10 ball valve 1 12 ZF01MF A0 02 base plate assembly 1 13 ZF01MF 30 00 pump Bushings 4 14 WZQB01 00 00 air pump 1 15 ZF01MF 20 00 fan pole assembly 1 16 ZF01MF A0 03 fan head assembly 1 17 ZF01MF 10 03 rear guard 1 18 ZF01MF 10 22 rear grill nut 1 19 ZF01MF 10 02 fan blade 1 20 ZF01MF 10 21 blade nut 1 21 ZF01MF 10 01 front guard 1 22 FV9144 00 03 nozzle housing...

Page 13: ... near you Call the number below to get the nearest service center This warranty does not include the air or water filters which are expendable parts that can wear out from normal use within the warranty period This warranty applies for only 90 days if this product is ever used for commercial or rental purposes auraMIST Inc 5210 Village Parkway Rogers AR 72758 The model number and manufacturing dat...