Remove the screw of the push-in connector and water flow control valve. (fig. 2)
Push the connector ring and pull out the air filter hose from the push-in connector, and the water
filter hose from the water flow control valve (fig 3).
Dispose of old filter.
Remove filter from package and orient the directional arrow so that the flow direction is towards the
up (fig. 4).
Push the hose into the push-in connector to connect the filters (fig.4).
Assemble the push-in connector and water flow control valve.
Reinstall filter cover (fig.5).
CAUTION:
DO NOT USE GASOLINE, THINNER, ALCOHOL, SOLVENTS OR
OTHER HARSH CLEANNERS OR CHEMICALS TO CLEAN THE FAN. THEY WILL
DAMAGE THE MISTING FAN.
Clean the unit with a soft cloth and mild soap solution.
Dry all parts completely.
Store the mist fan in a clean and dry place.
PROBLEM
CAUSE
CORRECTION
Misting fan not running
1. Power cord is not connected
2. Switch is in the “OFF” position
1. Connect power cord
2. Switch mist fan on high, medium ,low and
positions
Unit not misting
1. Water faucet is OFF
2. Ball valve is OFF
3
. Misting valve in the ”CLOSED”
position
4. Water filter could be clogged
1. Open the water faucet
2. Switch the ball valve to ON position
3. Open valve (counterclockwise)
4. Replace water filter
Water streaming from
nozzle
1. Air pump is not working
2. Air flow is low
3. Air filter needs replacement
4. Air hose leaks
5. Foreign object in nozzle
1. Turn on the mist ON/OFF switch
2. Change the intake filter of air pump
3. Replace air filter
4. Turn off mist fan motor, and feel any air
leaks on hoses
5. Order and replace nozzle
Mist is not balanced on
three nozzle
1. Low water flow
2. Water hose leaks
1. Adjust the water flow control valve
2. Turn off mist fan motor, and feel any air
leaks on hoses
Storage