25
Assembly Instruction
KS 4 S12 24V DC
06
I
nstallatIon
step
8
c
:
Note cable routing!
(see chapter „
C
able
routinG
“)
Note soft run mode!
(see chapter „
S
oft
run
moDe
“)
Check swiveling area! (see chapter
„
S
afety
CheCK
anD
p
erforminG
t
eSt
r
un
“).
!
!
Fit casement bracket
F41
with screws (
M5
).
Make sure it is parallel to casement edge.
„Casement bracket“ center and „chain out-
put“ must be in line.
Make sure they are parallel to casement edge.
!
28
18
n
ote
If required, use washers corresponding to the
used screws.
M5
par
allel
parallel
RA
FL
Attach drive to the frame brackets
K134
.
Secure the drive with screws
.
RA
FL
Frame brackets
K134
anscrewn (
M5
).
Casement
bracket F41
1x screw
M3x20
2
1
Connect control voltage (e.g. using a tester) and move
out the chain approx. 100 mm.
n
ote
For multi-drive operation actuate all drives
together.
RA
FL
Ks4
K134
3
Secure chain in the casement bracket
F41
with
screw
.
Ks4
Ks4
F41
K134
F41
1
3
4
1
2
FL
Frame bracket
K134
4x self-tapping
screws
M5x10
3
4
nsK
HsK
reference edge
42
±
2
RA
F41
1
M5
min.
8
parallel
on site
reference edge
on site
m
ounting
r
iGiD
DriVe
mountinG
on
the
CaSement
- main closing edge or auxillary closing edge
- inward opening windows
max. 4 Nm
max. 4 Nm
Summary of Contents for KS4 S12 24V DC R