TD- Documentation
Page 14 of 68 219-100-0-0-1.0.doc
Mounting Instruction
Chain drive KSA xxx-24 V / 230V
7
Chain drive KSA xxx in 230V AC
Detailed diagrams / overview
Dimension sheet KSA 2-S2 / KSA 2 MP / KSA MP in 230V AC
306
40
56
L
Chain key for mechanical loosening
adjustment screw for
chain pre-tension
16
Operation parameters
Rated voltage “U”:
Cut-off current “I”:
Max. pressure force “F”:
Max. pulling force “F”:
Stroke “s”:
230 V AC, 50 Hz
ca. 0,2
100 to 600 N (
)
depending on type and stroke
300 to 600 N (
)
depending on type and stroke
200 to 1000 mm 5 %
+
Stroke speed
with 2/3 nominal load and 24 V DC:
7,5 to 15 mm/s (
)
depending on type and stroke
IP 32
30%
not possible
- 5°C to +75°C (
)
environmental class I
opening against nominal load / closing with nominal load support
Protection class:
Duty cycle “ED” (for 10min):
Synchronized operation:
Ambient temperature range:
General performance:
see dimension sheet
Installation length L:
Technical description / product features
Soft start a. soft load disconnection, electronically controlled (MP)
Aluminum housing, natural-colored anodized (E6/C-0)
Parallel operation at all drive versions possible
Chain made of stainless steel with rigid back, deflection sidewards
Maintenance-free (drive)
Lacquering with RAL-palette possible
Optional covering profile for uniform design
Stepless optimization for smooth operation via adjustment of
chain tension
Versions
= with integrated electronic disconnection
= with integrated programmable microprocessor
S2
MP
End position indicator (option) “CLOSE” (MP)
PVC cable, type
, length approx. 5m
LiYY
Adaptable to special structural requirements via
programmable microprocessor MP
(e.g. stroke shortening)
* Technical Specifications for individual drive version see separate
Technical Data Sheet
250 = 537 1200 = 1020
1500 = 1173
500/600 = 715
800 = 816
1000 = 918
(at s) L L
300/400 = 613
of max. 8 drives
Parallel operation: