TD- Documentation
Page 40 of 68 219-100-0-0-1.0.doc
Mounting Instruction
Chain drive KSA xxx-24 V / 230V
Assembly procedure for Mounting brackets:
K84-1 / C-1 / E-1
for outward opening windows: Frame- or latch and post assembly
on HSK
Install customer-provided junction box and make electrical connection (pages 62 & 63)
- near the window / must be easily accessible later
- avoid installation area with big temperature fluctuations- danger of condensation
- mind cable length of drives, standard length approx. 5m
- Ensure that a later removal of the connection cable is possible if necessary
AK
max.10m
Check safety of assembled system
and conduct trial run
see page 61
Route cable on frame and / or waler
- the cable must adapt to pivoting angle of the drive (lay with strap)
- Cable must be protected against damage such as shearing off, kinking, cracking
(e.g. with a cable protection conduit)
Check pivoting range
- Drive must be able to traverse freely
with connection cable
!
In case the pivoting range is being
limited by the bracket, the cable entry
must be changed !
(for procedural steps see page 25)
possibly replacing the cable exit
Changing cable exit and / or
side for cable exit
Carry out procedure accordingly as
described on page 25
A
AK
Possibility of routing of connection cable
- Route cable according to on-site situation
- Ensure that cable doesn't get damaged during opening and closing
(e.g. by kinking, shearing off, squashing)
for multiple application on one casement
Cable conduit
surface-mounted
Cable conduit
flush-mounted
Junction box
surface-mounted
Junction box
flush-mounted
17