TD- Documentation
Mounting Instruction
Chain drive KSA xxx-24 V / 230V 219-100-0-0-1.0.doc
Page 61 of 68
Attention:
After completion of assembly, specified protection requirements for health and safety have to be met in accordance with
machine directive 2006/42/EG.
For windows within handling area (under a height of 2,5m from the bottom edge of the window to the finished
floor level) a
warning sign
must be attached in a clearly visible way to the casement or frame!
Furthermore, a risk assessment must be made by the installer of a power driven window.
The protection class stipulated by the planer must be complied with!
23
Consideration of the safety
and trial
operation
Activation
element
OPEN
CLOSE
Possible damages with improper assembly
Conduct trial run
- visual check of movement of casement / pre-tension of the chain
- stop immediately in case of fault
- check for poss. collision with facade and adjust configuration of drives
accordingly
Distortion of casement and
breakage of window pane
Without synchronization of drives
resp. white wires are not connected
Check safety of assembled system
-
- check mounting (brackets, mounting brackets) and tighten as necessary
connect control voltage
Cable junction box for
extension of cable
FL
RA
Collision
Safety scissors may not
limit drive stroke
Install bottom hung window safety scissors according
to window material and profile.
These prevent damage in case of a faulty drive.
Safety scissors must correspond to the specified
opening width and mechanism of the window.
SW2,5
ca
.
5
The pretension of the chain may be set at
- see page 24
bottom hung windows
never connect drives
directly to 230V AC
power supply
II
A