52
KS 2
(24 V DC / 230 V AC)
Multi-drive operating: Window drive „Set A“ with M-COM and locking drive
Always connect
the
M-COM
to the
24V
side!
The
drive „Set A“
is a factory configured set.
Included in the delivery are:
Master
: KS2 S12 230V AC R with voltage output 24V DC
Slave
: KS2 S12 24V DC R with connecting cable on the engine side
Options:
Programmable special functions and
sequence control with locking drives.
Configuration is done by
M-COM
.
e
leCtriC
C
onneCtion
230V / 24V
M-COM
KS2 (R)
WH
BN
BU
WH
BN
BU
230 V AC
24 V DC
FVUx
24 V DC
KS2 (R)
230 V AC
24 V
08
Drive:
Set A
Junction box
site-supplied
24 V DC
- Voltage output
230 V AC
- Voltage input
KS2 connecting cable:
24V DC,non-halogen
~ 3m, 3 x 0,5 mm
2
n
ote