10
KS 2
(24 V DC / 230 V AC)
D
ata
s
heet
D
ata
S
heet
KS2 S2 230v aC r / L
26
41
5
13
12
13
L
s
283
R
s
26
L
13
12
13
283
41
5
L
Application: Natural ventilation as single drive
Internal load dependend cut-off switch S2 in OPEN / CLOSE direction
Parallel connection up to 8 drives in one group
TECHNICAL DATA
U
N
Rated voltage
230V AC (50 Hz)
I
N
Rated current
0,13 A
I
A
Cut-off current
0,2 A
P
N
Rated power
30 W
DC
Duty cycle
5 cycles (ED 30 % - ON: 3 min. / OFF: 7 min.)
Protection rating
IP 32
Ambient temperature range
-5 °C ... +60 °C
F
Z
Pulling force max.
200 N
F
A
Pushing force max.
s > 600 mm only for pulling application
F
H
Pullout force
1.800 N (fastening depended)
Chain
Stainless steel, without protruding rivet heads.
Simple connection to casement brackets.
Small bending radii allow maximum opening
angles of small windows.
Connecting cable
non-halogen, grey 6 x 0,75 mm², ~ 3 m
v
Speed
10,0 mm/s
10,0 mm/s
s
Stroke
50 – 800 mm
L
Length
see order data
Sound pressure level:
≤
70 dB (A)
50
0
150
100
200
500
400
600
300
200
Zug
Pull
Schub
Push
s
(mm)
F
(N)
800
230V
ORDER DATA
s [mm]
L [mm]
Version
Finish
PU / pcs.
Part.-No.
200
475
KS2 200 S2 230V R (right)
E6/C-0
1
494920
KS2 200 S2 230V L (left)
E6/C-0
1
494720
300
520
KS2 300 S2 230V R
E6/C-0
1
494930
KS2 300 S2 230V L
E6/C-0
1
494730
400
570
KS2 400 S2 230V R
E6/C-0
1
494940
KS2 400 S2 230V L
E6/C-0
1
494740
500
685
KS2 500 S2 230V R
E6/C-0
1
494950
KS2 500 S2 230V L
E6/C-0
1
494750
600
685
KS2 600 S2 230V R
E6/C-0
1
494960
KS2 600 S2 230V L
E6/C-0
1
494760
800
765
KS2 800 S2 230V R
E6/C-0
1
494980
KS2 800 S2 230V L
E6/C-0
1
494780
(Right)
(Left)
02
Summary of Contents for 521620
Page 57: ...57 KS2 24 V DC 230 V AC Notes 08...
Page 58: ...58 KS2 24 V DC 230 V AC Notes 08...
Page 60: ...9000000201_V5 0_KW17 21...