49
KS 2
(24 V DC / 230 V AC)
Top hung / projecting top-hung casement - outward opening
Bottom-hung casement - inward opening
2 mm
2 mm
short side
short side
C
overing
of
the
D
rive
Determine fastenings.
Produce drill holes with appropriate cross-section.
For the mounting dimensions refer to the hole layout
drawings „
i
nStaLLation
Stepe
8
“.
Align the cover profile
on the profile brackets
proportionally and centrally and fit.
Attach end caps
and with screw M3
fasten.
Screw on profile brackets
.
Number of profile brackets
depends on the length of
the cover profile
: < 2 m length = 2 pieces
> 2 m length = 3 - 4 pieces
Determine length of cover profile
:
Length cover profile
= total distance between the
profile brackets
(outer edge) + 4 mm.
Use a saw to shorten the cover profile
to the required
length.
Deburr saw cut edge.
Carefully clear away drilling swarfs to prevent
seals from being damaged.
Avoid surface scratches, for example by using
masking tape.
I
nstallatIon
step
8
b
:
i
nStaLLing
the
Cover
profiLe
Ensure that you saw the profile perpendicular.
length cover profile
=
total distance between the
profile brack
ets
(outer edge)
+ 4 mm
The end cap
it exactly into the cover pro-
file
uand form a flush edge. In the case of
covers between post and post end caps
are not required.
M5
07
total distance between the
profile brack
ets
(outer edge)
n
ote
n
ote
Ensure the correct positioning of the cover
profile
(short side facing upwards).
Open casement electrically if appropriate
(to have a better access to the screws
).
4
4
5
7
6
4
4
Summary of Contents for 521620