16
KS 2
(24 V DC / 230 V AC)
D
ata
s
heet
/ P
reParing
a
ssembly
Drive positioning: Asymmetrical
Asymmetrical linkage of casement bracket or frame bracket can be
used in case of lack of space on the window frame / casement.
Drive positioning: Symmetrical
Symmetrical linkage of casement bracket or frame bracket
should always be preferred to an asymmetrical one.
Advantage:
• for a Tandem drive application, combination of drives
in R / L version can be used
• uniform force transmission to the window
• uniform casement pressure (tightness)
230V
OPTIONS
Special model
PU / pcs.
Part.-No.
Drive housing painted in RAL colours
Lump sum for coating
516030
Specify at order stage:
1 – 20
516004
21 – 50
516004
51 – 100
516004
ab 101
516004
For 24V drives: Extension of the standard connection cable length to:
5 m – non-halogen, grey – 3 x 0,5 mm²
501034
10 m – non-halogen, grey – 3 x 0,5 mm²
501036
5 m – non-halogen, grey – 5 x 0,5 mm²
501054
10 m – non-halogen, grey – 5 x 0,5 mm²
501056
For 230V drives: Extension of the standard connection cable length to:
5 m – non-halogen, grey – 6 x 0,75 mm²
501164
10 m – non-halogen, grey – 6 x 0,75 mm²
501166
For 24V drives: Microprocessor programming S12
Electronic stroke reduction 24V S12
524190
Programming drives 24V / 230V S12
524180
For 230V drives: Microprocessor programming S12
Programming synchronised multi-drive systems 230V S12
495588
Electronic stroke reduction (drives 230V AC)
495590
Programming drives 24V / 230V S12
524180
Optional accessories for drives with S12
PU / pcs.
Part.-No.
M-COM Configuration module for synchronised multi-drive systems
1
524177
24V
Check:
• unequal force transmission to the window
• window statics allows unequal force distribution
• unequal casement pressure (tightness)
D
rive
poSitioning
: S
ymmetry
or
aSymmetry
02
03
1/2 FAB
FAB
F
xxx
KS
2
=
=
1/2 FAB
FAB
F
xxx
KS
2
Summary of Contents for 521620