39
KS 2
(24 V DC / 230 V AC)
a
ssembly
of
the
D
rive
Determine fastenings.
Produce drill holes with appropriate cross-section.
For the mounting dimensions refer to the hole layout
drawings „
i
nStaLLation
Stepe
3 - 5
“ or project-specific
documents and drawings).
Secure fasteners against loosening; e.g. by applying
removable thread-locking compound such as “Loctite”.
Carefully clear away drilling swarfs to prevent
seals from being damaged.
Avoid surface scratches, for example by using
masking tape.
Note cable routing!
(see chapter „
C
abLe
routing
“)
Note softlauf modus!
(see chapter „
S
oft
run
moDe
“)
Check swiveling area! (see chapter
„
a
fety
C
heCK
anD
p
erforming
teSt
run
“).
FL
RA
max. 4 Nm
M5
(SW4)
FL
RA
RA
3
2
6
1
6
4
1
3
Apply the control voltage of the
KS 2
drive
(e.g. using
a tester).
Move out the chain of
KS 2
drive
~ 100 bis 150 mm.
n
ote
For multi-drive operation actuate all
KS 2
drives
together
.
(see chapter:
E
lEctric
c
onnEction
)
Secure the chain of
KS 2
drive - with screw
-
in the casement bracket
F41
.
k 94
r
igiD
Drive
mounting
DireCtLy
on
the
winDow
frame
- main closing edge or auxillary closing edge
- inward opening windows
Attach the
KS 2
drive
in the frame brackets
K94
.
Secure the
KS 2
drive
with self-tapping screws
M5
and washers
(max. 4 Nm).
n
ote
Screws - for mounting on the window - are to
be provided by the customer!
I
nstallatIon
step
6
b
:
nsk
hsk
Make sure they are parallel to casement edge.
The drive body must lie completely flush on
the window frame surface.
Screw the
KS 2
drive
- with on-site screws
(
M5
) - onto window frame.
06
ks 2
f 41
ks 2
ks 2
FL RA
M5
15
parallel
1
ks 2
site-supplied
reference
edge
Summary of Contents for 521620