Electromechanical control unit
Counter gear mechanism for end positions CLOSED and OPEN
Standard: Single switches (1 NC and 1 NO; not galvanically isolated) for each end position
Options:
●
Tandem switches (2 NC and 2 NO) for each end position, switches galvanically isolated
●
Triple switches (3 NC and 3 NO) for each end position, switches galvanically isolated
●
Intermediate position switch (DUO limit switching), adjustable for any position
Limit switching
Torque switching adjustable for directions OPEN and CLOSE
Standard: Single switch (1 NC and 1 NO) for each direction, switches not galvanically isolated
Options: Tandem switches (2 NC and 2 NO) for each direction, switches galvanically isolated
Torque switching
Potentiometer or 0/4 – 20 mA (RWG)
Position feedback signal, ana-
logue (option)
Continuous indication, adjustable indicator disc with symbols OPEN and CLOSED
Mechanical position indicator
Blinker transmitter (standard for SQEx, option for SQREx)
Running indication
Standard: Resistance type heater, 5 W, 24 V AC, (internal supply)
Heater in switch compartment
For nominal voltage and 40 °C ambient temperature and an average load with running torque or modulating torque according to separate
technical data. The type of duty must not be exceeded.
1)
Technical data for limit and torque switches
2 x 10
6
starts
Mechanical lifetime
Silver plated contacts:
30 V AC/DC
U min.
250 V AC/DC
U max.
20 mA
I min.
5 A at 250 V (resistive load)
3 A at 250 V (inductive load, cos phi = 0.6)
I max. AC current
0.4 A at 250 V (resistive load)
0.03 A at 250 V (inductive load, L/R = 3 µs)
7 A at 30 V (resistive load)
5 A at 30 V (inductive load, L/R = 3 µs)
I max. DC current
Gold plated contacts:
5 V
U min.
30 V
U max.
4 mA
I min.
400 mA
I max.
Technical data for blinker transmitter
10
7
starts
Mechanical lifetime
Silver plated contacts:
10 V AC/DC
U min.
250 V AC/DC
U max.
3 A at 250 V (resistive load)
2 A at 250 V (inductive load, cos phi
≈
0.8)
I max. AC current
0.25 A at 250 V (resistive load)
I max. DC current
Technical data for handwheel activation switches
10
6
starts
Mechanical lifetime
Silver plated contacts:
12 V DC
U min.
250 V AC
U max.
3 A at 250 V (inductive load, cos phi = 0.8)
I max. AC current
3 A at 12 V (resistive load)
I max. DC current
59
SQEx 05.2 – SQEx 14.2 / SQREx 05.2 – SQREx 14.2
AMExC 01.1
Technical data
Summary of Contents for AMExC 01.1
Page 70: ...15 2 ATEX certificate 70 SQEx 05 2 SQEx 14 2 SQREx 05 2 SQREx 14 2 Certificates AMExC 01 1...
Page 71: ...71 SQEx 05 2 SQEx 14 2 SQREx 05 2 SQREx 14 2 AMExC 01 1 Certificates...
Page 72: ...72 SQEx 05 2 SQEx 14 2 SQREx 05 2 SQREx 14 2 Certificates AMExC 01 1...
Page 73: ...73 SQEx 05 2 SQEx 14 2 SQREx 05 2 SQREx 14 2 AMExC 01 1 Certificates...
Page 74: ...74 SQEx 05 2 SQEx 14 2 SQREx 05 2 SQREx 14 2 AMExC 01 1...
Page 75: ...75 SQEx 05 2 SQEx 14 2 SQREx 05 2 SQREx 14 2 AMExC 01 1...