©2004 AUGIER SA.
VI-61
Adr. R/W Mode Label
Detail Bit clear
Bit set
Default
value
Comments
100 R/W
Brightness control
0 : Stop
1 : Brightness B1
2 : Brightness B2
3 : Brightness B3
4 : Brightness B4
5 : Brightness B5
6 : Brightness B6
7 : Brightness B7
8 : Brightness B0
(Heat)
101 R/W Sup
Serial link ID
1
1 to 32
102 R/W Sup Serial
link
speed
9600 In
Baud
2400, 4800, 9600,
19200
Bit0 -
-
Bit1 -
EFD
Opt.
Bit2 -
Fault
lamps
Opt.
Bit3
Option
Time
mon.
Bit4
Opt.4-20mA
Bit5
Opt. Wig Wag
Bit6
Bit7
Bit8
Bit9
Bit10
Bit11
Bit12
Bit13
Bit14
104 R/W Sup Options
Bit15
106 R
Operating time clock
In hours and
minutes, see note 1
110 R
Powered-on time
clock
In
hours
and
minutes, see note 1
114 R
Brightness B0 time
clock
In
hours
and
minutes, see note 1
118 R
Brightness B1 time
clock
In
hours
and
minutes, see note 1
122 R
Brightness B2 time
clock
In
hours
and
minutes, see note 1
126 R
Brightness B3 time
clock
In
hours
and
minutes, see note 1
130 R
Brightness B4 time
clock
In
hours
and
minutes, see note 1
134 R
Brightness B5 time
clock
In
hours
and
minutes, see note 1
138 R
Brightness B6 time
clock
In
hours
and
minutes, see note 1
142 R
Brightness B7 time
clock
In
hours
and
minutes, see note 1
146 R/W Sup
Operating time clock
level
10000
Hours
In hours and
minutes, see note 1
Note1 : The 4 bytes are coded: H2-H1-H0-MM (H2,H1,H0 in BCD and MM in hexadecimal)
Example:
Reading operating time:
Contents of address @106: 5623 in Hexadecimal, and of address @108 : 7935 in hexadecimal
The time is interpreted as: 562379 Hours and 53 minutes