3 Wire Ground Switched Door Locks
In this application, the red wire provides a ground pulse during arming (pulsed ground lock) output.
Connect the red wire to the wire that provides a low current ground signal from the factory door lock switch to
the factory door lock control relay.
The green wire provides a ground pulse during disarming (pulsed ground unlock) output. Connect the
green wire to the wire that provides a low current ground signal from the factory door unlock switch to the
factory door lock control relay.

3 Wire Positive Switched Door Locks
In this application, the red wire provides a positive pulse during disarming ( 12 volt unlock) output.
Connect the red wire to the wire that provides a low current positive signal from the factory door unlock switch
to the factory door lock control relay.
The green wire provides a positive pulse during arming ( 12 volt lock) output. Connect the green
wire to the wire that provides a low current positive signal from the factory door lock switch to the factory door
lock control relay.

Resistive Circuits, As Well As 4 Wire Polarity Reversal and 5 Wire Alternating 12 Volt Door Lock
Control Circuits
These applications require the use of additional components which may include relays, fixed resistors, or for
convenience, the AS 9159 Door Lock Interface.  Refer to the AUDIOVOX Door Lock Wiring Supplement and or
the Audiovox fax back service for information on your particular vehicle for properly connecting to these types
of circuits.

COMPLETING THE INSTALLATION

Antenna Wire : Be sure to extend the thin black antenna wire to it’s full length and cable tie into place where
it cannot be damaged. Avoid wrapping this wire around major, high current wire looms.
Adjusting the Shock Sensor : The sensitivity of the pre - detect circuit, where used, is automatically set 30%
less sensitive than the full trigger circuit.
Using a small screwdriver, gently turn the adjustment screw fully counterclockwise. ( DO NOT over turn this
screw. Maximum rotation for this adjustment is 270° ). Close the hood and trunk lids, and arm the alarm. Wait
6 seconds for the accessories trigger zone to stabilize, then firmly strike the rear bumper with the side of a
closed fist considering the amount of force required to break a window.
CAUTION : Never perform this test on the vehicle’s glass, as you may break the window.
Turn the adjustment screw clockwise ( increasing sensitivity ) about ¼ turn and re-test. Repeat this
procedure until the alarm sounds. Ultimately, one firm strike to the rear bumper will cause the alarm to emit
pre - detect warning tones.
WARNING ! Setting the sensitivity too high can cause false alarms due to noise vibrations from passing

trucks and heavy equipment. To decrease sensitivity, turn the adjustment screw counter clockwise.

Wire Dressing : Always wrap the alarm wires in convoluted tubing, or with a spiral wrap of electrical tape.
Secure these looms along the routing using cable ties. This will ensure that the alarm wires are not damaged
by falling onto hot or sharp moving surfaces in the vehicle.
Operation : Take a few moments to check off the appropriate option boxes in the owner’s manual and to fully

explain the operation of the system to your customer.

Page 5

Summary of Contents for Prestige APS-25KB

Page 1: ...ll vehicle doors are closed arming is suspended until the last door is closed Thisfeatureprotectsthevehicleintheeventyouforgettoarmthesystemusingthekeychaintransmitter When the optional door lock interface is installed the doors will operate according to the position of dip switch number2 Thissystemisshippedinthepassivemode thereforenomodificationsarerequiredtomakethesystemoperate as a Passive ala...

Page 2: ...tter programming guide included in this package for more details regarding transmitter button assignments and system functions INSTALLATIONOFMAJORCOMPONENTS CONTROLMODULE Selectamountinglocationinsidethepassengercompartment upbehindthedash andsecureusingtwoscrews provided The control module can also be secured in place using cable ties Do not mount the control module in the engine compartment as i...

Page 3: ...RING THE SYSTEM WHITE WIRE 12 VDC PULSED PARKING LIGHT OUTPUT 15 A MAX This wire is provided to flash the vehicle s parking lights Connect the white wire to the positive side of one of the vehicle s parking lights RED FUSED WIRE VOLTAGE SENSING 12 VDC CONSTANT BATTERY SOURCE This wire controls the sensitivity of the voltage sensing circuit which detects the turning on of an interior light whenadoo...

Page 4: ... the vehicle s door courtesy light switches have a 12 volt output when the door is opened most Fords and some Imports you must connect this wire to the positive output from one of the door switches In most cases the purple wire will only need to be connected to one door switch no matter how many doors the vehicle has WARNING Do not use the purple wire if the vehicle has ground output type door swi...

Page 5: ...ts COMPLETING THE INSTALLATION Antenna Wire Be sure to extend the thin black antenna wire to it s full length and cable tie into place where it cannot be damaged Avoid wrapping this wire around major high current wire looms Adjusting the Shock Sensor The sensitivity of the pre detect circuit where used is automatically set 30 less sensitive than the full trigger circuit Using a small screwdriver g...

Page 6: ...128 5732B 6 of 12 2000 Audiovox Corporation 150 Marcus Blvd Hauppauge N Y 11788 128 5732A ...

Page 7: ... on oublierait d armer le système par l émetteur de la chaîne porte clés Lorsque l interface de verrouillage de porte en option est installée les portes fonctionnent suivant la position du commutateur DIP 2 À la livraison ce système est en mode passif par conséquent aucune modification n est nécessaire pour que le système fonctionne en alarme Passive En mode alarme active on ne peut armer le systè...

Page 8: ...mentetfonction dedéclenchementdelasirène Toutefonctionadditionnelledusystème canal2 3durécepteur doitêtreprogramméelors de l installation Ces fonctions peuvent être attribuées au bouton 2 de l émetteur ou aux boutons 1 et 2 enfoncés simultanément Seréférerauguidedeprogrammationdel émetteur comprisedanscepaquet pourobtenirplusdedétails concernant les attributions des boutons des émetteurs ainsi que...

Page 9: ...ETENSION ALIMENTÉENPERMANENCEPARLATENSIONSONSTANTE 12VCC DELABATTERIE Ce fil commande la sensibilité du circuit de détection de tension qui détecte la mise en marche d un éclairage intérieur lors de l ouverture d une porte il détecte également l éclairage des feux de stationnement ou des phares et dans de nombreux cas déclenche l alarme lors de la mise en marche d un ventilateur électronique de re...

Page 10: ... relais que sur les fils d alimentation de la bobine de démarrage à faible courant comme l indique le schéma de câblage FIL BLANC SORTIE DE FEUX DE STATIONNEMENT À IMPULSIONS 12 VCC 15A MAX Ce fil est fourni pour faire clignoter les feux de stationnement du véhicule Brancher le fil blanc sur le côté positif de l un des feux de stationnement du véhicule FILS BLEU FONCÉ SORTIE À IMPULSIONS DE 300 MA...

Page 11: ...aximale et d utiliser des serre câbles à différents endroits où on ne peut l endommager Eviter d enrouler ce fil autour des faisceaux principaux de fils comportant des courants forts RÉGLAGE DU DÉTECTEUR DE VIBRATIONS La sensibilité du circuit pré détection est automatiquement réglée à 30 de moins que la sensibilité du circuit de déclenchement total À l aide d un petit tournevis faire tourner la v...

Page 12: ...128 5732B 12 of 12 2000 Audiovox Corporation 150 Marcus Blvd Hauppauge N Y 11788 128 5732A ...

Reviews: