Continuous sealer
D541
Description Continuous sealer
17
4.3 Control panel
4.3.1 Coolrun
mode
The coolrun mode prevents burning of the PTFE fibreglass belts. After the
machine has been stopped, the heater is switched off; however, the blower and
the motor will continue to run. When the sealing temperature has dropped to
below 80°C, the sealer is switched to stand-by mode and the blower and the
motor will also be switched off.
Figure 4-2: Control panel
1.
Start/stop
Press and hold for at least 1 second to start or stop
the sealer.
When the sealer is switched on, the display shows the
actual sealing temperature.
When the actual sealing temperature upon switching
off is over 80°C, the sealer will first switch to Coolrun
mode.
2.
Up/down
Press to increase or reduce the temperature setting.
3.
Display
Shows the actual sealing temperature. While making
changes, the set value is displayed (and the value in
the display is followed by a point).
1
3
2