To replace the component:
1.
If you are not using an optional HP input cable or the ring tongues you crimped
previously, with the ground cable disconnected from the 48V power source, crimp the
ring tongues to the power and ground cables coming from the 48V source.
Note:
The power supply uses two power ring tongues and one ground ring tongue. They
are not interchangeable.
2.
Remove the safety cover from the terminal block on the front of the power supply.
3.
Remove the screws from the terminal block.
Note:
The minimum nominal thread diameter of a pillar or stud type terminal must be 3.5