Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
with respect to the correctness of information in this document. Copyright by AUDI AG.
State of charge
(SOC):
Measure:
“≥ 80% (12.5 V)”
No further measures necessary.
“SOC < 80% (12.5
V) und SOC ≥ 10%
(11.6 V)”
Charge battery ⇒ Rep. gr. 27 ; Battery;
Charging battery .
“< 10% (11.6 V)”
Charge battery ⇒ Rep. gr. 27 ; Battery;
Charging battery , and attach mirror hanger
for “Battery defective”.
– Record charge level in maintenance table.
Note
If if is not possible to read off the state of charge in the instrument
cluster, measure the battery's no load voltage
3.9.2
Vehicles with transport mode OFF
Special tools and workshop equipment required
♦ Battery tester - VAS 6161-
The battery is located in the luggage compartment.
Removal steps:
– Remove luggage compartment back panel trim ⇒ General
body repairs, interior; Rep. gr. 70 ; Luggage compartment trim
panels; Overview of fitting locations - luggage compartment
trim panels .
– Remove luggage compartment floor ⇒ General body repairs,
interior; Rep. gr. 70 ; Luggage compartment trim panels;
Overview of fitting locations - luggage compartment trim pan‐
els .
Procedure:
– Switch on battery tester - VAS 6161- and select “QC check,
new vehicles”.
– Use battery tester - VAS 6161- to measure voltage between
battery clamps.
– Use results of test to determine following measures:
Battery
tester
shows:
Measure:
“Battery
Good”
No further measures necessary.
“Charge
fully now”
Charge battery ⇒ Rep. gr. 27 ; Battery; Charging
battery .
“Battery
Faulty”
Charge battery ⇒ Rep. gr. 27 ; Battery; Charging
battery , and attach mirror hanger for “Battery de‐
fective”.
– Record charge level in maintenance table.
Audi R8 2015 ➤
Maintenance - Edition 03.2016
3. Maintenance
19