10
PAGING COMMANDS
PGRQ
Paging request
Command:
WOS
Arguments:
pppp^ww^0000rrrr^l
pppp: priority level 0000 to 9999
ww: wallpanel port (must be 00 for ARU)
rrrr: zones to page : 32 bit bit0=zone 1 bit31=zone 32
l:
local=0
or
global=1
(must be 1 for ARU)
Feedback:
+
+: Acknowledge
Example: A001 send request to S001 for zone4
#|S001|A001|PGRQ|0999^01^00000008^0|U| <CR><LF>
ARU replies: #|A001|S001|PGRQ|+|crc|<CR><LF> (for ACK if paging not busy in requested zones)
or: #|A001|S001|PGRQ|-|crc|<CR><LF> (for NACK if paging busy in requested zones)
PG
Paging start/stop
Command:
PG
Arguments:
s
s:
status
start=1
stop=0
Feedback:
+
+: Acknowledge
Example: start paging
#|S001|A001|PG|1|U|<CR><LF>
MISC COMMANDS
WOS
Check which relay units are online
Command:
WOS
Arguments:
Feedback:
+
+: Acknowledge
Example: who is online
#|ALL|web|WOS||U|<CR><LF>
ARU replies: #|web|S001|OS|+|crc|<CR><LF>
GTIME
Get time
Command:
GTIME
Arguments:
Feedback:
hh:mm:ss
Example: get time from relay unit
#|SOO1|web|GTIME||U|<CR><LF>