5
SGEVNT
Set event:
Command:
SGEVNT
Arguments:
xx
xx:
event
nr
Feedback:
^xx^cc^hhmmss^yymmdd^ww^dest^cmd^param^U
xx: event nr
cc: header, must be 55 for valid event
hhmmss: time for event to execute
yymmdd: date for event to execute
ww: weekday for event to execute
dest:
Address
of
ARU
cmd:
cmd
to
execute
can be SRON, SROFF, SRPULS, SRBUT
param:
parameters
of
command
Example: Get event
#|S001|F001|SGEVNT|01|U|<CR><LF>
ARU replies:
#|F001|S001|EVNT|^01^55^170500^181206^01^S001^SRON^00000055^U|crc|<CR><LF>
SXEVNT
Execute event:
Command:
SXEVNT
Arguments:
xx
xx:
event
nr
Feedback:
+
+: Acknowledge
Example: Execute event 01
#|S001|F001|SXEVNT|01|U|<CR><LF>
ARU replies: #|F001|S001||crc|<CR><LF>
SAS
Set address switch unit
Command:
SAS
Arguments:
xxx
xxx: address of the unit
On receive the LED flashes.
Feedback:
+
+: Acknowledge, if switch is pressed
Example: Set unit address 199
#|ALL|web|SAS|199|U|<CR><LF>, when received, led starts flashing
ARU replies: #|web|S199|SAS|+|crc|<CR><LF> after switch has been pressed.
ASF
End Set address switch unit
Command:
ASF
Arguments:
xx
xx:
event
nr
Feedback:
+
+: Acknowledge
Example: End set address
#|ALL|web|ASF||crc|<CR><LF>
ARU replies: led stops flashing after receive of command