9
SDELOFF
Switches all relays off with a delay.
Command:
SDELOFF
Arguments:
dddd
dddd: 0 to 9999ms delay between each relay
Feedback:
+
+: Acknowledge
Example: swith all relays off with 100ms delay time
#|S001|web|SDELOFF|0100|crc|<CR><LF>
ARU replies: #|web|S001|S|crc|<CR><LF> and status from all relays
#|ALL|S001|SZSET|007F|crc|<CR><LF>
#|ALL|S001|SZSET|003F|crc|<CR><LF>
#|ALL|S001|SZSET|001F|crc|<CR><LF>
#|ALL|S001|SZSET|000F|crc|<CR><LF>
#|ALL|S001|SZSET|0007|crc|<CR><LF>
#|ALL|S001|SZSET|0003|crc|<CR><LF>
#|ALL|S001|SZSET|0001|crc|<CR><LF>
#|ALL|S001|SZSET|0000|crc|<CR><LF>
Note: All relays will be switched off with a delay, direction relay8 -> relay1
This function can also be programmed to do at powerup
- with the command “SDPU” argument ‘1’
- by placing jumper A into lower position
The delay time is set by the command “SDPUD” argument 0 to 9999
The potentiometer is used for timing when delay is set to 0