The AC-160-DIN Wireless multipurpose relay for DIN rails 

The AC-160-DIN wireless multipurpose relay for DIN rails 

1 / 2 

MLZ54301 

The AC-160-DIN wireless multipurpose relay (MFR) is a bi-directional 

component of the JABLOTRON 100 system. The MFR copies the status 
of selected PG outputs when enrolled to the JA-10xK control panel.  

The MFR can also be used as a stand-alone device, then it follows 

status of up to 64 one-way communicating detectors of the JA-15x 
series and keyfobs of the JA-15xJ MS and JA-16xJ.  The MFR then 
switches accordingly to the selected mode (modes: extended copy, 
impulse, change of status, always switches off and block the relay).  
It has galvanically and securely isolated relay contacts for switching  
a power load of 230 V / 16 A. This product can only be installed by  
a trained technician with a valid certificate issued by an authorised 
distributor.

 

The  output  relay  can  also  be  controlled  manually  by  the  button  (3)  

on the front panel. In stand-alone mode the button serves for enrolling 
devices and setting the module properties

.

 

Installation 

 

 

The  device  can  only  be  connected  
to  mains  electricity  by  a  person  who  has 
an adequate electrotechnical qualification. 
It 

provides 

single 

pole 

switching  

and doesn’t provide safety isolation

.

 

The  relay  module  is  meant  to  be  installed 

on a DIN rail. There must be a JA-11xR radio 
module  enrolled  to  the  control  panel  
to  ensure  cooperation  with  the  system.  
It  occupies  one  position  in  the  JA-100 
system. 

Figure 1: 1 – mains power terminals 230 V AC;  

2 – LED indicators; 3 – Learn / Set button;  

4 – cover tabs; 5 – connector for AN-868 

external antenna; 6 – relay output terminals 

1.  Install the relay onto the DIN rail. 
2.  Connect  the  power  wires  (230  VAC)  

to  the  terminals  (1),  and  turn  the  power 
on. 

3.  Proceed  according  to  the  control  panel 

installation manual. Basic procedure: 
a. 

When the MFR has been turned on, 
the  ‘RELAY’  indicator  lights  green. 
The 

yellow 

LED (2) 

lights 

permanently  to  indicate  the  MFR  has  not  been  enrolled  
to  the  system  yet  and  that  no  detector  has  been  enrolled  to 
the MFR. 

b. 

Using 

F-Link

  software,  select  the  required  position 

in the 

Devices

  window  and  launch  the  enrollment  mode  

by clicking on the 

Enroll

 option. 

c. 

By  pressing  the 

Learn/Set

  (3)  button  longer  then  3 s  

(until  the  yellow  LED  starts  flashing)  the  relay  sends  
the  enrollment  signal  to  the  control  panel.  Enrolling  
to  the  control  panel  is  confirmed  when  the  yellow  LED  
turns off. 

4.  Test  the  MFR  function  by  pressing  the  button  (3).  

After  approximately  0.5 s  the  output  relay  is  actived.  A  switched 
relay is indicated by a red LED (‘RELAY’). 

5.  Connect the controlled device to the terminals (6). 

Notes: 

  The relay goes to standby mode, when the power is disconnected 

or  communication  with  the  control  panel  is  lost  for  more  than 
1 minute. When the MFR has lost communication with an enrolled 
device  then  the  restoration  interval  is  20  minutes.  Loss 
of communication is indicated by a permanent yellow ‘ERR’ LED.  

  When the mains or communication with a control panel is restored, 

the MFR  returns to the status given  by  pre-defined settings  within 
2 minutes (for wireless detectors with a periodical link test, such as 
the JA-151M, the interval is 9 minutes)  

  The MFR doesn’t maintain periodical communication with keyfobs. 

  It  is  also  possible  to  the  MFR  to  the  system  by  entering  

the  production  code  via  the  F-Link  software.  A  sticker  with  
the  production  code  is  on  the  rear  side  of  the  relay.  All  digits  
in the code are required (example: 1400-00-0000-0001) 

  JA-18x detectors are not compatible with the relay 

  Multiple-input  detectors  such  as  the  JA-150M  are  always  enrolled  

to  one  position  and  the  relay  is  only  triggered  by  the  first  input  
of the detector. The second input has no effect. 

  After  each  press  of  the  Learn/Set  button  the  MFR  changes  

its status after 0.5 s, as well as when a signal is transmitted or while 
entering the MFR’s service mode – indicated by the ‘RELAY’ LED. 
When  a  control  panel  is  already  enrolled,  the  function  can  be 
disabled. See the settings below. 

Setting the module properties 

The  module  properties  can  be  set  in  the 

Devices

  window  

of  the 

F-Link

  software.  When  at  the  module  position,  use  

the 

Internal settings

 option to open a dialogue window where you can 

set the following options:

 

Manual relay control:

 Enabled: a short press of the Learn/Set button (3) 

changes  the  relay  state  (switches  ON/OFF).  Manual  control  is  always 
possible  even  in  a  situation  when  the  MFR  doesn’t  communicate  
with the control panel. Manual control can be completely disabled. 

Reacts to PG(s):

 Enables activation of the MFR by one or more control 

panel PG outputs. 

Common timer:

  Determines the period of time during  which the output 

relay will be switched ON. The function differs according to the pre-set mode 
of the associated detector. This parameter serves for setting the timing of the 
switching  impulse  of  an  impulse  detector  or a keyfob.  A  status-mode  type  
of detector with an “extended copy” reaction set makes the relay stay active 
for the whole time even when the detector goes to standby. The timer can 
be set in pre-defined steps or your own time in the F-Link software (from 1s 
to 23h 59min 59s). 

Enrolled devices:

  This  window  includes  64  positions  to detectors 

and  keyfobs.  There  are  two  options  to  them  to  the  relay:  the  first  is  
to enter the production code into the 

production code

 field. The second 

is  enrolling  them  via  the  Learn/Set  button  which  is described  in  the 

Enrolling  the  detectors  and  keyfobs 

chapter.  In  this  case  it  is 

recommended  to  use  the  internal  menu  only  to  check  on  or maintain  
the modes of the enrolled detectors.  

 

 

The  MFR  internal  settings  do  not  work  in  
on-line  mode.  That´s  why  it  is  not  possible 
to  enroll  devices  via  F-Link  SW  sending  
an  enrollment  signal.  It  is  only  possible  
by  entering  the  serial  number  and  saving 
the settings.

 

Mode:

  This  option  determines  how  the  MFR  will  react  

to the activation of an enrolled device. 

 

None:

 the device has no function 

 

Extended  copy:

  This  reaction  is  only  for  the  detectors.  

The  MFR  will  be  switched  ON  for  as  long  as  the  detector  
is  activated.  After  the  detector  goes  to  standby  mode,  the  MFR 
extends activation with time set by the ‘common timer’ function. 

 

Switch  On/Switch  Off: 

This  reaction  is  only  for  keyfobs  

of the  JA-15xJ  and  JA-16xJ  series.  The  A(C)  button  switches 
the MFR on and the B(D) button switches it off. 

 

Impulse:

  detector  activation  will  switch  ON  the  MFR  for  

a pre-defined  time  given  by  the  Common  timer.  The  MFR  can  
be  kept  switched  on  as  long  as  the  configured  keyfob  button  
is pressed. Up to 60 seconds maximum.

 

 

Change  status:

  detector  activation  or  pressing  the  configured 

keyfob button changes the MFR’s status

 

 

Always 

switching 

off:

 

detector 

activation 

or pressing  

the configured keyfob button always switches off the MFR if there’s 
no  active  selected  PG  output  in the control  panel  or  a  status 
detector with Extended copy mode.

 

 

Block:

  A  particular  active  status-mode  detector  blocks  switching 

the MFR by other detectors for its whole activation period. The A(C) 
button  on  an  enrolled  keyfob  blocks  the  MFR  on  and  the  B(D) 
button  unblocks  it.  When  blocking  is  over,  the  relay  is  activated 
again  as  long  as  there  is  a  request  to  switch  on  the  MFR  by  any 
status-mode  detector  or  a  PG  output.  Blocking  is  indicated  
by the flashing green LED. Blocking during other detector activation 
is indicated by alternate flashing in green / red of the ‘RELAY’ LED.

 

Note: 

The highest priority of the relay is blocking, next is triggering  

a status detector or a PG output and then everything else (timer, switch 
on/off, status change), so that a switched on relay can’t be switched off 
by, for example, a PG output. 

FW upgrade 

1.  A  FW  upgrade  can  be  performed  by  a  user  with  Service 

authorisation. 

2. 

The 

F-Link

 SW is needed to perform the upgrade. 

3.  Using a thin tool (screwdriver) slightly press the tab (4) and take off 

the relay front cover. It allows access to the Micro USB connector. 

4.  Connect  the  PC  to  the  relay  using  a  Micro  USB  cable.  

A  FW  upgrade  can  be  performed  with  a  connected  control  panel  
or offline with only the MFR connected. 
The  MFR  can  be  powered  by  230 V AC,  the  USB  circuits  
are  galvanically  isolated.  A  power  supply  is  not  required  
as the relay is powered via the USB cable from the PC. 

5.  The  relay’s  BOOT  mode  is  indicated  by  flashing  the  green  /  red 

‘RELAY’ LED. 

6.  Then continue as if you are doing an upgrade via 

F-Link

 software: 

&RQWUROSDQHOĺ8SJUDGH)LUPZDUH

 

ĺWKH

FW upgrade file pack 

(it is a part of the F-Link installation pack, or it can be independently 