background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Summary of Contents for NI 9482

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...MANUAL AND SPECIFICATIONS NI 9482 4 Channel SPST Electromechanical Relay Module ni com manuals Deutsch Fran ais Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg...

Page 3: ...ot meet the same safety ratings and specifications Refer to the documentation for each component in the system to determine the safety ratings and specifications for the entire system Related Informat...

Page 4: ...9482 in a manner not specified in this user manual Product misuse can result in a hazard You can compromise the safety protection built into the product if the product is damaged in any way If the pro...

Page 5: ...t devices and circuits connected to the module are properly insulated from human contact Caution When module terminals are hazardous voltage LIVE 42 4Vpk 60 VDC you must ensure that devices and circui...

Page 6: ...mits for electromagnetic compatibility EMC as stated in the product specifications These requirements and limits are designed to provide reasonable protection against harmful interference when the pro...

Page 7: ...nce with the instructions in the product documentation Furthermore any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it un...

Page 8: ...ts for Electrical Fast Transients or lightning Surge which are normally applied to ports intended for connection to the electrical distribution system For applications where connection to the electric...

Page 9: ...2 provides connections for four electromechanical relay channels Figure 2 NI 9482 Pinout 0 3 0 1 2 3 4 5 6 7 8 9 CH0a CH0b CH1a CH1b CH2a CH2b CH3a CH3b NC NC Artisan Technology Group Quality Instrume...

Page 10: ...o create a secure connection when connecting more than one wire to a single terminal on the NI 9482 LEDs Each channel has an LED that indicates the state of the channel A channel LED is lit when the c...

Page 11: ...or CHb to the other lead of the power supply Figure 3 Connecting a Load When the channel is turned on the terminal connected to the load drives current or applies voltage to the load When the channel...

Page 12: ...n National Instruments recommends that you either use ferrules to terminate wires to the detachable screw terminal connector or use the NI 9927 backshell kit to protect the connections Figure 4 Wiring...

Page 13: ...Typically when a system is in sleep mode you cannot communicate with the modules In sleep mode the system consumes minimal power and may dissipate less heat than it does in normal mode Related Informa...

Page 14: ...tching voltage 60 VDC max 250 Vrms max Switching current per channel One channel on 2 5 A max at 30 VDC 1 A max at 60 VDC 2 5 A max at 250 Vrms Two channels on 2 A max at 30 VDC 1 A max at 60 VDC 2 A...

Page 15: ...ad 20 000 000 operations Electrical connecting to load 100 000 operations MTBF Contact NI for Bellcore MTBF or MIL HDBK 217F specifications Power Requirements Power consumption from chassis Active mod...

Page 16: ...e module number Screw terminal wiring 0 511 mm diameter 24 AWG to 2 053 mm diameter 12 AWG copper conductor wire with 10 mm 0 39 in of insulation stripped from the end Torque for screw terminals 0 5 N...

Page 17: ...test Measurement Category II is for measurements performed on circuits directly connected to the electrical distribution system This category refers to local level electrical distribution such as that...

Page 18: ...l or the Online Product Certification section Electromagnetic Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement control and labo...

Page 19: ...scientific or medical equipment that does not intentionally generates radio frequency energy for the treatment of material or inspection analysis purposes Note For EMC declarations and certifications...

Page 20: ...ication column Shock and Vibration To meet these specifications you must panel mount the system Operating vibration sinusoidal IEC 60068 2 6 5 g 40 Hz to 500 Hz 0 062 in double amplitude 10 Hz to 40 H...

Page 21: ...temperature IEC 60068 2 1 IEC 60068 2 2 40 C to 85 C Ingress protection NI 9482 IP 30 NI 9482 with screw terminal connector attached IP 40 Operating humidity IEC 60068 2 56 10 to 90 RH noncondensing...

Page 22: ...cts is beneficial to the environment and to NI customers For additional environmental information refer to the Minimize Our Environmental Impact Web page at ni com environment This page contains the e...

Page 23: ...nters National Instruments WEEE initiatives and compliance with WEEE Directive 2002 96 EC on Waste and Electronic Equipment visit ni com environment weee RoHS National Instruments RoHS National Instru...

Page 24: ...Instruments product Product registration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance wit...

Page 25: ...opriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information about end user license agreements...