output will be disabled until the probe 3 alarm is cleared.
Note 19. Step End Alarm:
Step ending alarm setting. When
Step End Alarm
is set to
“ON”, the buzzer will beep 4 times when each step is finished. It is useful to notify the
user the cooking step is finished. Users can turn it off if no buzzer sound is wanted at the
finish of each step.
Note 20. Backlight Level:
LCD backlight level setting. The higher the value, the brighter
the LCD display. 0 is lowest brightness. 10 is highest brightness.
Note 21. BUZZ:
Built-in buzzer option. By default, built-in buzzer is enabled when the
alarm is triggered (BUZZ = ON). To turn off built-in buzzer, change BUZZ to OFF.
Note 22. Data Interval (for WIFI model only):
Data Logging Sampling Interval. This
parameter controls the temperature sampling interval, which will be used for data export
function and plot display on AuberWIFI app. The controller will store 5 data traces in total:
SV, Probe 1 reading (cabinet), Probe 2 reading (food probe), Probe 3 reading and the
output power percentage. Each trace can store up to 300 data points. The temperature
plot of the AuberWIFI App has two scales. One can display the latest 300 data points and
other can display the latest 120 data points. The default setting of Dwell time is 1 minute
per sample. At this setting, 300 minutes (or 5 hours) of data points can be stored. Users
can display the plot in either 5 hours or 2 hours. The dwell time can be set in the range of
1 minute to 5 minutes. Table 4 shows the available plot scales for the corresponding
dwell time.
Table 4. Available options for Data Interval.
Data Interval Option
(Interval time per sample)
Maximum Logging Time
Plot Display Option
1-minute
5-hour
2-hour/5-hour
2-minute
10-hour
4-hour/10-hour
3-minute
15-hour
6-hour/15-hour
4-minute
20-hour
8-hour/20-hour
5-minute
25-hour
10-hour/25-hour
Note: Once the data interval time is set, the app can only display the temperature plot in
the two scales listed in the table. If you want to change the dwell time in the middle of
cooking, you will lose all the data logged before the change. If you want keep the data,
you should export the data before change this setting.
Note 23. nFlt:
Power line digital filter. This filter is for rejecting the power line
interference. There are three settings: “Auto” for auto-detect mode (default), “A” for 50