5.  Erect the side walls and cut the opening or orient the      
 

pre-fabricated opening. Frame with 2” x 2” lumber (or    

 equivalent).
6.  Pull the unit outward through the opening and bend all    
 

four flanges outward 90 degrees along the lanced lines.

Installation in standard 6 gallon water heater opening with 

Standard Door Kit

Installation in standard 10 gallon water heater opening with 

Large Door Adapter Kit

7.  To prevent water leaks, caulk thoroughly around the  

 

 

backside of the flanges over the lanced bend slots. Caulk  

 

the perimeter of the opening (or substitute 1” x 3/8” Butyl  

 Tape).
8.  Push the unit to the wall against the caulking and secure  
 

the corner brackets behind the unit flanges but snug to   

 

the corner of the enclosure. Complete the installation    

 

by  inserting #8 screws in all the flange holes, ensuring    

 

that the casing is installed completely square allowing for  

 

a good door fit. 

 

an “air tight” seal must be the final result.

gEnEraL inStaLLation

The following instruction describes the most common type 
of installation for the water heater. However, there are other 
approved methods such as baggage compartment and flush 
mounting. Consult your Field Auditor, Account Manager, or the 
Atwood Service Department if you have additional questions.
These steps assume the proper location has been determined 
and is being installed at the OEM prior to erecting the walls. 

noTe:

 Parts bagged and included with the unit in the box are 

the corner filler brackets and push on water line connectors.

1.  Locate the water heater on the floor of the coach at pre-  
 

determined location. The unit must be permanently  

 

 

supported at the same level as the bottom of the sidewall  

 

cutout (by the floor or a raised floor).

2.  To install the unit on carpeting, assure the addition  

 

 

of metal or wood under the unit is added and extends    

 

a minimum of three inches beyond the width and  

 

 

depth of the appliance enclosure. Minimum clearance    

 

requirement is zero (except front door for proper operation  

 

and service).

3.  If risk of future connection leakage and damage of  

 

 

adjacent area is of concern, install a drain pan under the  

 

unit with drainage to outside of vehicle.

4.  Connect plumbing to water lines with fittings provided    
 

taking care to make correct “COLD” and “HOT”  

 

 

orientation. Connect 3/8” FM  flared LP gas line to 3/8” M  

 

flared gas fitting.

 

  a.  Allow flexibility in water and gas lines so the unit   

 

   

can be pulled through the sidewall opening at least  

 

   

one inch past the skin, allowing for sealing step.

 

  b.  Assure the water and gas line grommets continue  

 

   

to be intact and properly inserted in the case holes,  

 

   

with no gaps or openings where the line passes    

m

 

caution

 PrODUCT DAMAGe

Gas  connection  must  be  made  using  TWO  (2)  wrenches                      

to avoid twisting and damaging line.

Damage voids the Warranty!

Cold In

Hot Out

Gas Connection

Corner Brackets

(4)

Adapter

Summary of Contents for OD50

Page 1: ...s Btu 01__________ Generation CW______ Cold Weather Kit m critical installation warnings Install in recreation vehicles only RV s are recreation vehicles designed as temporary living quarters for recreation camping or travel use having their own power or towed by another vehicle All combustion air must be supplied from outside the RV and all products of combustion must be vented to outside the RV ...

Page 2: ...rmined and is being installed at the OEM prior to erecting the walls NOTE Parts bagged and included with the unit in the box are the corner filler brackets and push on water line connectors 1 Locate the water heater on the floor of the coach at pre determined location The unit must be permanently supported at the same level as the bottom of the sidewall cutout by the floor or a raised floor 2 To i...

Page 3: ...periodic inspection of product of listed equipment or materials as meeting requirements for Relief Valves and Automatic Gas Shutoff Devices of Hot Water Supply Systems ANSI Z21 22 CSA 4 4 Valve must have maximum set pressure not to exceed 100 psi Install replacement valve into opening provided and designated for this purpose on water heater Installation must conform with local codes or in the abse...

Page 4: ... COLD PACK OPTIONAL IGN CONT SPARK SENSE WIRING SCHEMATIC GREEN GREEN RED RED PURPLE BROWN BROWN RED RED RED PURPLE RED RED BLUE BLUE LOCKOUT LAMP OPTIONAL MPD 90211 m CAUTION FIRE DO NOT smoke or have any flame near an open faucet GENERAL INFORMATION LP and Water system must be turned on Have gas pressure tested periodically Should be set at 11 inches of water column with three appliances running...

Page 5: ...warm ranging from 70 F to 90 F it is recommended that the modulating valve adjustment be placed in the MIN position This reduces the gas input of the heater to keep the water temperature from getting too hot with high incoming water temperature Winter Operation During the winter months when incoming water temperatures are cooler ranging from 45 F to 70 F it is recommended to place the modulating v...

Page 6: ...ulting the trouble shooting guide If problems still persist contact Atwood or an authorized service center Only a qualified technician should do any work involving the gas system A periodic visual check of the burner flames should be done by observing the flame through the peep hole in the heat exchanger There should be blue flame with minimum or no yellow tipping Burner maintenance should be perf...

Page 7: ...inter summer valve is in the proper position for the temperature of the incoming water 3 Water flow too low for incoming water temperature 5 Be sure there is a battery in the system Never connect the heater directly to a power converter Some converters have circuits that are not pure DC This can cause malfunctions or damage to the heater and is not covered by warranty 6 Be sure that no water mixin...

Page 8: ...lacement of burner orifices c cleaning or adjustment of burner assembly d cleaning or adjustment of flue e adjustment of pressure relief valve 4 In the event of a warranty claim the owner must contact in advance either an authorized Atwood Service Center or the Atwood Service Department Warranty claim service must be performed at an authorized Atwood Service Center can be found online www atwoodmo...

Page 9: ... ont pas été réparées L installation et la réparation doivent être effectuées par un installateur qualifié une agence de service ou le fournisseur de gaz Explication du numéro du modèle OD_____________________ À la demande On demand 50________________ Entrée en milliers de BTU 01__________ Génération CW______ Kit de temps froid m AVERTISSEMENTS CRITIQUEs SUR L INSTALLATION À installer dans les véh...

Page 10: ... y a d autres méthodes approuvées comme celles dans le coffre à bagages ou le boîtier encastré Pour toute question supplémentaire veuillez consulter votre vérificateur sur place votre directeur de compte ou le service à la clientèle Atwood Avant de commencer assurez vous que l emplacement approprié a été déterminé et installé par le FEO avant l érection des murs REMARQUE Les pièces mises en sac et...

Page 11: ...e l interrupteur en position OFF ROUGE est le courant positif d entrée de 12 V c c VERT est la mise à la terre de 12 V c c BLEU est le signal de verrouillage de 12 V c c positif Voir l illustration de la configuration de commutation type 7 Pour prévenir les fuites d eau calfeutrez soigneusement le pourtour arrière des brides et sur les fentes pliées et perforées Calfeutrez le pourtour de l ouvertu...

Page 12: ... ouvrez le robinet d eau chaude de l évier de cuisine pendant plusieurs minutes avant d utiliser tout appareil électrique relié au système d eau chaude Si de l hydrogène gazeux est présent vous allez probablement entendre des sons tels que l air qui s échappe par le tuyau au moment où l eau commence à couler 1 Mettre en pression le système d eau en tournant sur la pompe ou la pression d eau de vil...

Page 13: ...débit dans les robinets et ou des pommes de douche Éliminer les restricteurs pour de meilleures performances 4 Propane pression du système de gaz doit être 11 W C en cours de fonctionnement Assurez vous que les réservoirs de propane comportent beaucoup de gaz et sont correctement régulés Cela doit être vérifié par un technicien agréé Atwood Si le problème persiste s il vous plaît contacter le cent...

Page 14: ... 90290 LISTE DES PIÈCES DU CHAUFFE EAU DÉPANNAGE La plupart des problèmes sont facilement résolus en consultant le guide de dépannage Si le problème persiste veuillez contacter Atwood ou un centre de service agréé Seul un technicien qualifié devrait effectuer tout travail impliquant le système de gaz Une vérification périodique visuelle des flammes du brûleur devrait être faite en observant la fla...

Page 15: ...avec le terminal seulement 5 Assurez vous que l alimentation du ventilateur a 12 volts lorsque de l eau coule et qu il n y a pas d obstacles dans le conduit d air 6 Assurez vous que mano contact est clôturé par la vérification la tension à travers des terminaux devrait être de 0 volts si lisant 12 volts vérifient l obstruction de conduite ou l obstruction dans la ligne de sens tuyauterie L eau ne ...

Page 16: ...rais d essence de téléphone de déplacement d hébergement le manque à gagner ou les dommages matériels Certains États n autorisent pas les exclusions ou les restrictions des dommages accessoires ou consécutifs par conséquent il est possible que les restrictions ou les exclusions précédentes ne s appliquent pas à vous 10 Les garanties implicites se limitent à une période de deux 2 ans Certains États...

Reviews: