7

2.  Water pump is not functioning properly. Repair or replace  
 pump.
3.   If the heater cycles as the pump cycles, a pressure  

 

 

accumulator tank is needed in the water system. If you    

 

have an accumulator tank, check to see if it has become  

 

filled with water. If it has, drain it so that it contains air    

 only.
4.  Air is in the water line. Bleed air by turning on all water    
 taps.
5.  Water source pressure fluctuating too low causing loss    
 

of flow, check incoming water source pressure, should be  

 

a minimum of 30 psi.

burner ignites but Water Temperature is Too low

1.  The water flow may be so high as to exceed the capacity  
 

of the heater particularly if your supply water is very cold.  

 

Slow the water flow.

2.  The gas pressure may be too low. Be sure the gas flow   
 

control valve is in full “on” position.

3.  Check the gas pressure while the water is on at full flow.  
 

The LPG pressure should be the “manifold pressure” as  

 

shown on the specification label while the heater is  

 

 

running. A gas-testing gauge should be installed on the   

 

manifold tap so that it may be read while heater is  

 

 

running. If it is too low, turn up the gas regulator to the    

 

proper pressure. This should only be done by a qualified  

 technician.
4.  The gas flow may be too low due to improper gas line    
 

diameter (under 3/8 inch outside diameter). The gas line   

 

may be excessively long (over 20-30 feet) or the on/off    

 

solenoid at the tank (if you have one) may have an orifice  

 

that is too small (under 3/16th of an inch).

5.  Check the heater door louvers and flue pipe for airflow    
 

obstructions and clean.

6.  Check that the “winter/summer” valve is in the proper   
 

position for the temperature of the incoming water.

Water Temperature Too low at lower Water flow 
rates

1.  Check that the “winter/summer” valve is in the proper    
 

position for the temperature of the incoming water.

2.  Be sure to momentarily turn hot water flow to high, then  
 

back to the lower flow when turning on a water faucet.    

 

This will bring the gas flow to the required higher setting.

3.  For single lever shower controls you may have to adjust   
 

internal temperature control to a higher setting to allow    

 

for more hot water flow to properly activate the water    

 heater.

Water Temperature is Too Hot or no Temperature 
control.

1.  Fuel tank regulator is set too high and manifold pressure  
 

as described above Have the regulator checked by a    

 

qualified technician.

2.  Check that the “winter/summer” valve is in the proper    
 

position for the temperature of the incoming water.

3.  Water flow too low for incoming water temperature.

5.  Be sure there is a battery in the system. never connect   
 

the heater directly to a power converter. Some converters  

 

have circuits that are not pure DC. This can cause  

 

 

malfunctions or damage to the heater and is not covered  

 

by warranty.

6.  Be sure that no water-mixing valve has been left in the on  
 

position, using the showerhead as a shut off. This will    

 

permit water to bypass the water heater and bleed cold   

 

water into the hot water system. Always turn off both hot  

 

and cold water valves after using.

7.  Be sure that the bypass valve at the water plumbing  

 

 

connections is in the “off” position. An open valve can    

 

also permit water to bypass heater, causing it not to fire.

8.  Locate the ECO, high temperature switch (two red wires)  
 

at the upper left hand of the heat exchanger. Check for   

 

open circuit condition. The ECO should be reset by  

 

 

pushing the reset button when temperature drops below  

 

160 degrees.

There is no ignition When Water is on (Power vent is 
running)

1.  Be sure the gas valve at the tank is “On”, there is gas in  
 

the tank and the gas line is purged of all air.

2.  Check that the ignition wire is plugged into the spark    
 

tower on the ignition control and is not touching anything  

 else.
3.  Check flame site hole to see if igniter is sparking from the  
 

probe to the burner. Bend ignition wire to adjust to proper  

 

gap dimension or contact Atwood or you’re nearest  

 

 

authorized service representative.

4.  Check that there are no cuts or breaks in the wire. Align it  
 

so that it is not in contact with anything but the terminal.

5.  Be sure that the power vent fan has 12 volts to it when    
 

there is water flowing and there are no obstructions in the  

 

flue pipe.

6.  Make sure pressure switch is closed by checking for  

 

 

voltage across terminals, should be 0 volts, if reading    

 

12 volts check for flue obstruction or obstruction in sense  

 

line tubing.

no Water flows from Tap When Tap is Turned on.

1.  Be sure that water supply is turned on and that there are  
 

no obstructions.

burner Turns on but Temperature fluctuates 
erratically.

1.  May be caused by excessive restriction at the water  

 

 

outlets, showerheads, aerators or water strainers. These  

 

should be cleaned and any showerhead flow restrictor    

 removed.
2.  The gas modulating valve is out of calibration. Consult    
 Atwood.

Heater comes on but rapidly cycles on and off.

1.  Water flow is too low. Increase flow at a tap. Clean all    
 

aerators and shower head screens to assure at least .5   

 

GPM of water flow

Summary of Contents for OD50

Page 1: ...s Btu 01__________ Generation CW______ Cold Weather Kit m critical installation warnings Install in recreation vehicles only RV s are recreation vehicles designed as temporary living quarters for recreation camping or travel use having their own power or towed by another vehicle All combustion air must be supplied from outside the RV and all products of combustion must be vented to outside the RV ...

Page 2: ...rmined and is being installed at the OEM prior to erecting the walls NOTE Parts bagged and included with the unit in the box are the corner filler brackets and push on water line connectors 1 Locate the water heater on the floor of the coach at pre determined location The unit must be permanently supported at the same level as the bottom of the sidewall cutout by the floor or a raised floor 2 To i...

Page 3: ...periodic inspection of product of listed equipment or materials as meeting requirements for Relief Valves and Automatic Gas Shutoff Devices of Hot Water Supply Systems ANSI Z21 22 CSA 4 4 Valve must have maximum set pressure not to exceed 100 psi Install replacement valve into opening provided and designated for this purpose on water heater Installation must conform with local codes or in the abse...

Page 4: ... COLD PACK OPTIONAL IGN CONT SPARK SENSE WIRING SCHEMATIC GREEN GREEN RED RED PURPLE BROWN BROWN RED RED RED PURPLE RED RED BLUE BLUE LOCKOUT LAMP OPTIONAL MPD 90211 m CAUTION FIRE DO NOT smoke or have any flame near an open faucet GENERAL INFORMATION LP and Water system must be turned on Have gas pressure tested periodically Should be set at 11 inches of water column with three appliances running...

Page 5: ...warm ranging from 70 F to 90 F it is recommended that the modulating valve adjustment be placed in the MIN position This reduces the gas input of the heater to keep the water temperature from getting too hot with high incoming water temperature Winter Operation During the winter months when incoming water temperatures are cooler ranging from 45 F to 70 F it is recommended to place the modulating v...

Page 6: ...ulting the trouble shooting guide If problems still persist contact Atwood or an authorized service center Only a qualified technician should do any work involving the gas system A periodic visual check of the burner flames should be done by observing the flame through the peep hole in the heat exchanger There should be blue flame with minimum or no yellow tipping Burner maintenance should be perf...

Page 7: ...inter summer valve is in the proper position for the temperature of the incoming water 3 Water flow too low for incoming water temperature 5 Be sure there is a battery in the system Never connect the heater directly to a power converter Some converters have circuits that are not pure DC This can cause malfunctions or damage to the heater and is not covered by warranty 6 Be sure that no water mixin...

Page 8: ...lacement of burner orifices c cleaning or adjustment of burner assembly d cleaning or adjustment of flue e adjustment of pressure relief valve 4 In the event of a warranty claim the owner must contact in advance either an authorized Atwood Service Center or the Atwood Service Department Warranty claim service must be performed at an authorized Atwood Service Center can be found online www atwoodmo...

Page 9: ... ont pas été réparées L installation et la réparation doivent être effectuées par un installateur qualifié une agence de service ou le fournisseur de gaz Explication du numéro du modèle OD_____________________ À la demande On demand 50________________ Entrée en milliers de BTU 01__________ Génération CW______ Kit de temps froid m AVERTISSEMENTS CRITIQUEs SUR L INSTALLATION À installer dans les véh...

Page 10: ... y a d autres méthodes approuvées comme celles dans le coffre à bagages ou le boîtier encastré Pour toute question supplémentaire veuillez consulter votre vérificateur sur place votre directeur de compte ou le service à la clientèle Atwood Avant de commencer assurez vous que l emplacement approprié a été déterminé et installé par le FEO avant l érection des murs REMARQUE Les pièces mises en sac et...

Page 11: ...e l interrupteur en position OFF ROUGE est le courant positif d entrée de 12 V c c VERT est la mise à la terre de 12 V c c BLEU est le signal de verrouillage de 12 V c c positif Voir l illustration de la configuration de commutation type 7 Pour prévenir les fuites d eau calfeutrez soigneusement le pourtour arrière des brides et sur les fentes pliées et perforées Calfeutrez le pourtour de l ouvertu...

Page 12: ... ouvrez le robinet d eau chaude de l évier de cuisine pendant plusieurs minutes avant d utiliser tout appareil électrique relié au système d eau chaude Si de l hydrogène gazeux est présent vous allez probablement entendre des sons tels que l air qui s échappe par le tuyau au moment où l eau commence à couler 1 Mettre en pression le système d eau en tournant sur la pompe ou la pression d eau de vil...

Page 13: ...débit dans les robinets et ou des pommes de douche Éliminer les restricteurs pour de meilleures performances 4 Propane pression du système de gaz doit être 11 W C en cours de fonctionnement Assurez vous que les réservoirs de propane comportent beaucoup de gaz et sont correctement régulés Cela doit être vérifié par un technicien agréé Atwood Si le problème persiste s il vous plaît contacter le cent...

Page 14: ... 90290 LISTE DES PIÈCES DU CHAUFFE EAU DÉPANNAGE La plupart des problèmes sont facilement résolus en consultant le guide de dépannage Si le problème persiste veuillez contacter Atwood ou un centre de service agréé Seul un technicien qualifié devrait effectuer tout travail impliquant le système de gaz Une vérification périodique visuelle des flammes du brûleur devrait être faite en observant la fla...

Page 15: ...avec le terminal seulement 5 Assurez vous que l alimentation du ventilateur a 12 volts lorsque de l eau coule et qu il n y a pas d obstacles dans le conduit d air 6 Assurez vous que mano contact est clôturé par la vérification la tension à travers des terminaux devrait être de 0 volts si lisant 12 volts vérifient l obstruction de conduite ou l obstruction dans la ligne de sens tuyauterie L eau ne ...

Page 16: ...rais d essence de téléphone de déplacement d hébergement le manque à gagner ou les dommages matériels Certains États n autorisent pas les exclusions ou les restrictions des dommages accessoires ou consécutifs par conséquent il est possible que les restrictions ou les exclusions précédentes ne s appliquent pas à vous 10 Les garanties implicites se limitent à une période de deux 2 ans Certains États...

Reviews: