14
Set the multiplexer functions as follows:
(Press the Menu key of the multiplexer to enter the Unit Options menu.)
9 Unit Options
Unit Number:
001 (first Mux) or 002 (second Mux)
Communication Type:
RS 485
Baud rate:
9600 bps
PORT:
ON
** Protocol:**
B (If you see this line, the multiplexer has the new ROM)
** The old ROM version does not show Protocol selection option.
Multiplexer alarm inputs will function normally, but the Dome controller has no way of knowing about alarms
wired to the Multiplexer. If a Dome preset is required for such an alarm, you must connect the same alarm
input to both the multiplexer and Dome
.
Triplex setup:
Unit setup
Network Type: RS 485
Baud Rate:
9600 bps
Unit address:
001 ~ 128
Protocol:
B1
Summary of Contents for KB5000N
Page 2: ......
Page 3: ......
Page 11: ...3 Chapter 2 Installation and Configuration 2 1 USB Configuration of Fastrax Dome System...
Page 15: ...7 2 2 Basic Configuration of Fastrax Dome System Figure 1 Basic installation diagram...
Page 16: ...8 2 3 Configuration with DVR Figure 3 installation diagram with DVR...
Page 17: ...9 2 4 Configuration with MUX Figure 4 installation diagram with MUX...
Page 56: ......