25
Established:
Designer: Project manager:
Format:
Approved:
Drawing no.:
Revision:
Project:
Drawing name:
INDUSTRIVEJ 20, 9900 FREDERIKSHAVN, DENMARK
Phone +45 98 47 90 33 - Fax +45 98 47 92 91
E-mail: [email protected] - Homepage: www.rais.dk
Corrections:
D M Y
user
VISIO 1 Indbygningsmål kun Panel
04-05-2015
A3
A-A
B-B
A
A
B
B
E
E
VISIO 2 (uden afd
æ
kning)
Panel indbygning
Uden tekst
20
0
25
English
RAIS/
attika
- User manual for VISIO
VISIO 1 - Built-in dimensions
Wall opening VISIO 2 - 12.5 mm Fermacell with 25 mm mineral wool
Wall opening (height x width x depth) min. 432 x 770 mm (inner dimensions).
Inner distance to the back wall is min. 620 mm and to the side wall it is min. 1047 mm.
In case the stove is placed against a combustible wall, the back and side walls must be
made of 12.5 mm Fer 25 mm mineral wool. The mineral wool is facing the
stove.
The inner dimensions (wall opening) applies for installing the stove
without
outer front
cover (accessory). If a front cover is used, the wall opening is to be increased/corrected
equalling the thickness of the front cover.
A fireplace insert must never be built in tightly as steel expands during heating.
25 mm mineral wool
12,5 mm Fermacell
Construction of back & side wall.
12,5 mm Fermacell