VISIO 1 Indbygningsmål kun Panel
04-05-2015
A3
24
English
RAIS/
attika
- User manual for VISIO
Wall opening VISIO 1 - calcium silicate insulating boards
Wall opening (height x width x depth) min. 432 x 770 mm (inner dimensions).
Inner distance to the back wall is min. 620 mm and to the side wall it is min. 1047 mm.
In case the stove is placed against a combustible wall, the back and side walls must be
made of 50 mm calcium silicate insulating boards.
The inner dimensions (wall opening) applies for installing the stove
without
outer front
cover (accessory). If a front cover is used, the wall opening is to be increased/corrected
equalling the thickness of the front cover.
A fireplace insert must never be built in tightly as steel expands during heating.
12,5 mm Fermacell eller
50 mm calcium silicate
bords