background image

RMBC64-24D OPERATORS MANUAL 
 

 

 

 
 

(1) 

Charge Indicators 

 

The charge indicators (green LED’s) inform the operator that the charger is A, operating 
correctly. B, charging the cells and C, the cells have completed a full charge cycle. 
 
Each bank of four green LED’s above the charger sockets represents that charging circuit. 
 
When the power is first on, both the banks of charge indicator LED’s will flash twice. 
This informs the operator that the charger circuits have been internally checked and they 
are operating correctly. 
 
After the charge procedure has been initialized the charge indicators will start to flash and 
continue to flash until the battery is fully charged. 
 
When the battery or batteries are fully charged, the green charge indicators will turn to a 
constant light, indicating that the battery or batteries are fully charged. 
 
As the cells become fully charged, individual LED lamps within the bank will turn from 
flashing to constant. When all the green LED’s are constant within the bank and only 
then will the battery or batteries be fully charged. 

(1)  Charge Indicators 

Green LED’s 

 

Summary of Contents for RMBC64-24D HAWK

Page 1: ...RMBC64 24D HAWK 3 STAGE BATTERY CHARGER OPERATORS MANUAL 2012...

Page 2: ...RMBC64 24D ELECTRONIC BATTERY CHARGER INDEX Page Handling Requirements 1 Installation 1 Specifications 2 Overview 3 Functional Description 3 Operation 5 Trouble Shooting 11...

Page 3: ...tch is in the OFF position Lower back flap by twisting anti clockwise Zuse fasteners to expose mains input socket and ventilation fans Ensure both charger and mains is switched OFF before connecting p...

Page 4: ...570mm H x W x D Battery charge state Any level from flat to full Time between full charge operation 1 hour Time between full charge operation means that if the operator has fully charged the battery i...

Page 5: ...l be on with the top row of green LEDs flashing This indicates that all the charging circuits are operating correctly within the bank When the charge cycle is complete the red LEDs within that bank wi...

Page 6: ...Vss provides the necessary signal to the servo control loop which regulates the charging current The charger unit consists of two banks of sixteen individual chargers each delivering 0 3C at full cha...

Page 7: ...HAWK batteries together Various combinations of battery charge can be selected which include A Single battery on full charge B Two batteries on full charge C One battery on full charge and second batt...

Page 8: ...rcuits have been internally checked and they are operating correctly After the charge procedure has been initialized the charge indicators will start to flash and continue to flash until the battery i...

Page 9: ...ators representing the selected battery will illuminate and remain constant for as long as it takes to charge the appropriate cells When the cells are fully charged the appropriate status indicators w...

Page 10: ...ition informs the operator when the trickle charge system is in operation by emitting an audible intermittent bleep This alert can also be used to remind the operator when the batteries have completed...

Page 11: ...rocedure the LED will go out informing him her that the trickle procedure has stopped After the HAWK battery has been fully charged the main charging system turns off and the trickle charge commences...

Page 12: ...or The power indicator lamp informs the operator when illuminated that mains power is being supplied to the charger 12 Fuse An 8AMP Anti Surge fuse is fitted to this charger WARNING THIS CHARGER IS FO...

Page 13: ...p fuse not illuminated Check power from source Charger has power WARNING CHARGER MUST BE Neon mains light Charger fuse blown SWITCHED OFF FROM THE MAINS illuminated but not BEFORE OPENING FUSE HOLDER...

Reviews: