ATSI RMBC64-24D HAWK Operator'S Manual Download Page 13

 

RMBC64/24D ELECTRONIC BATTERY CHARGER 
 
Trouble  Shooting.

 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

* Note

 

The RMBC64/24D is designed to warn the operator that power is 

ON  

 

by the mains neon light being illuminated. 

 
 

The neon light is in front of the fuse to warn the operator 

NOT

 to open the  

 fuse holder until the mains has been 

SWITCHED OFF

, to avoid an 

electrical shock.   

RMBCPL 
MAINS 
POWER 
LEAD 

RMBCL 
HAWK 
CHARGER 
LEAD 

  HAWK 
  BATTERY 

  HAWK 
  BATTERY 

Mains 
Plug 

RMBC64/24D 
HAWK DOUBLE 
BATTERY CHARGER 

Problem

 

 

Possible Cause

 

 

 

Possible Remedy 

 
Charger no power. 

 

 

 

 

 

Check mains plug. 

Mains neon light 

 

No mains power 

 

Replace 13Amp fuse. 

not illuminated. 

 

 

 

 

 

Check power from source. 

 
Charger has power. 

 

 

 

 

 

WARNING CHARGER MUST BE

 

Neon mains light 

 

Charger fuse blown   

SWITCHED OFF FROM THE MAINS

 

illuminated but not 

 

 

 

 

 

BEFORE OPENING FUSE HOLDER

 

charging. (No LED’s   

 

 

 

 

Replace fuse with RMFA8 

flashing) 

 

 

 

 

 

 

* see note 

 
Charger green LED’s   

 

 

 

 

Check both ends are connected 

flashing but red LED’s 

RMBC24 lead not  

 

correctly and the rings are locked 

will not illuminate when 

connected 

 

 

on the Amphenol plug and socket. 

start button is pressed. 
 
Charger green LED’s   

 

 

 

 

Allow battery to cool for 1 hour 

flashing but red LED’s 

HAWK    

  

 

Note it is not recommended to use 

will not illuminate when         fully charged.   

 

full charge again when battery is 

button is pressed. 

 

 

 

 

 

fully charged. 

 

 

 

 

 

 

 

 

Trickle charge is sufficient to keep 

 

 

 

 

 

 

 

 

t

he battery topped up from full

 

 

 

 

 

 

Summary of Contents for RMBC64-24D HAWK

Page 1: ...RMBC64 24D HAWK 3 STAGE BATTERY CHARGER OPERATORS MANUAL 2012...

Page 2: ...RMBC64 24D ELECTRONIC BATTERY CHARGER INDEX Page Handling Requirements 1 Installation 1 Specifications 2 Overview 3 Functional Description 3 Operation 5 Trouble Shooting 11...

Page 3: ...tch is in the OFF position Lower back flap by twisting anti clockwise Zuse fasteners to expose mains input socket and ventilation fans Ensure both charger and mains is switched OFF before connecting p...

Page 4: ...570mm H x W x D Battery charge state Any level from flat to full Time between full charge operation 1 hour Time between full charge operation means that if the operator has fully charged the battery i...

Page 5: ...l be on with the top row of green LEDs flashing This indicates that all the charging circuits are operating correctly within the bank When the charge cycle is complete the red LEDs within that bank wi...

Page 6: ...Vss provides the necessary signal to the servo control loop which regulates the charging current The charger unit consists of two banks of sixteen individual chargers each delivering 0 3C at full cha...

Page 7: ...HAWK batteries together Various combinations of battery charge can be selected which include A Single battery on full charge B Two batteries on full charge C One battery on full charge and second batt...

Page 8: ...rcuits have been internally checked and they are operating correctly After the charge procedure has been initialized the charge indicators will start to flash and continue to flash until the battery i...

Page 9: ...ators representing the selected battery will illuminate and remain constant for as long as it takes to charge the appropriate cells When the cells are fully charged the appropriate status indicators w...

Page 10: ...ition informs the operator when the trickle charge system is in operation by emitting an audible intermittent bleep This alert can also be used to remind the operator when the batteries have completed...

Page 11: ...rocedure the LED will go out informing him her that the trickle procedure has stopped After the HAWK battery has been fully charged the main charging system turns off and the trickle charge commences...

Page 12: ...or The power indicator lamp informs the operator when illuminated that mains power is being supplied to the charger 12 Fuse An 8AMP Anti Surge fuse is fitted to this charger WARNING THIS CHARGER IS FO...

Page 13: ...p fuse not illuminated Check power from source Charger has power WARNING CHARGER MUST BE Neon mains light Charger fuse blown SWITCHED OFF FROM THE MAINS illuminated but not BEFORE OPENING FUSE HOLDER...

Reviews: