RMBC64-24D ELECTRONIC BATTERY CHARGER 

 

Overview. 
 

The RMBC64-24D has been designed for charging two HAWK batteries. 
 
Designed to provide all the intelligence to safely, consistently and efficiently fast charge 
the HAWK battery. 
 

Functional Description. 
 

At switch on from the mains the two top row banks of green LEDs will give two flashes 
to confirm that the charging circuits are operating correctly and that there is no 
malfunction with the charger. 
 
The unit is fitted with a selectable buzzer and a flashing green LED per channel to inform 
the operator when the battery or batteries are fully charged and has reverted to trickle 
charge. 
 
Two seconds after the flashes have finished, the charger is ready for use. 
 
Once either of the red start buttons have been pressed the charging process for that bank 
begins. 
 
Both the second, third, fourth and fifth row of red LEDs will be on, with the top row of 
green LEDs flashing. This indicates that all the charging circuits are operating correctly 
within the bank. 
 
When the charge cycle is complete, the red LEDs within that bank will be off and the top 
row of green LEDs will all be constant, together with the red trickle charge LED flashing, 
and if the audio alert is switched on the buzzer will be sounding. 
 
If the buzzer is switched in, it will sound when the last flashing green LED is constant 
informing the operator that the battery or batteries are fully charged and the charger has 
reverted to trickle charge. 
 
The charger has an automatic heat sensing shut down system as well as negative delta 
peak sensing to provide an added safeguard. 
 
The primary charging system is change of temperature over change of time with a max 
timer cut out. 
 
Validation checks confirm if the temperature range of the battery is either in or outside 
limits, or its end voltage (Edv) is too low, at which point the charger enters its pending 
stage until such time as these validation parameters come within limits. 
 

Summary of Contents for RMBC64-24D HAWK

Page 1: ...RMBC64 24D HAWK 3 STAGE BATTERY CHARGER OPERATORS MANUAL 2012...

Page 2: ...RMBC64 24D ELECTRONIC BATTERY CHARGER INDEX Page Handling Requirements 1 Installation 1 Specifications 2 Overview 3 Functional Description 3 Operation 5 Trouble Shooting 11...

Page 3: ...tch is in the OFF position Lower back flap by twisting anti clockwise Zuse fasteners to expose mains input socket and ventilation fans Ensure both charger and mains is switched OFF before connecting p...

Page 4: ...570mm H x W x D Battery charge state Any level from flat to full Time between full charge operation 1 hour Time between full charge operation means that if the operator has fully charged the battery i...

Page 5: ...l be on with the top row of green LEDs flashing This indicates that all the charging circuits are operating correctly within the bank When the charge cycle is complete the red LEDs within that bank wi...

Page 6: ...Vss provides the necessary signal to the servo control loop which regulates the charging current The charger unit consists of two banks of sixteen individual chargers each delivering 0 3C at full cha...

Page 7: ...HAWK batteries together Various combinations of battery charge can be selected which include A Single battery on full charge B Two batteries on full charge C One battery on full charge and second batt...

Page 8: ...rcuits have been internally checked and they are operating correctly After the charge procedure has been initialized the charge indicators will start to flash and continue to flash until the battery i...

Page 9: ...ators representing the selected battery will illuminate and remain constant for as long as it takes to charge the appropriate cells When the cells are fully charged the appropriate status indicators w...

Page 10: ...ition informs the operator when the trickle charge system is in operation by emitting an audible intermittent bleep This alert can also be used to remind the operator when the batteries have completed...

Page 11: ...rocedure the LED will go out informing him her that the trickle procedure has stopped After the HAWK battery has been fully charged the main charging system turns off and the trickle charge commences...

Page 12: ...or The power indicator lamp informs the operator when illuminated that mains power is being supplied to the charger 12 Fuse An 8AMP Anti Surge fuse is fitted to this charger WARNING THIS CHARGER IS FO...

Page 13: ...p fuse not illuminated Check power from source Charger has power WARNING CHARGER MUST BE Neon mains light Charger fuse blown SWITCHED OFF FROM THE MAINS illuminated but not BEFORE OPENING FUSE HOLDER...

Reviews: