background image

RMBC64-24D ELECTRONIC BATTERY CHARGER 

 

Introduction 
 
Handling Requirements 
 

Maximum stacking height. 

 

 

 

2 x Units on top of each other. 

 

Minimum clearance for ventilation.   

 

25mm each side and 50mm at rear. 

 
Power requirements.   

 

 

 

110 >240 volts AC @ 6.5 Amps. 

 
Weight. 

 

 

 

 

 

16.5Kgs. 

 
Dimensions.   

 

 

 

 

200 x 380 x 570mm (H x W x D) 

 

Installation. 
 

 

 

Remove front cover by un-clipping side clips. 

 
 

 

Check that the power switch is in the 

OFF

 position. 

 
 

 

Lower back flap by twisting anti-clockwise “Zuse” fasteners to expose 

 

 

mains input socket and ventilation fans. 

 
 

 

Ensure both charger and mains is switched 

OFF 

before connecting power 

 

 

lead to charger socket. Ensure both charger socket and power lead are  

 

 

clean and dry before connecting. 

 

Connect power lead (RMBCPL) by pushing plug into socket via locating 
pins. 
 
Connect charger lead (RMBCL24) plug to the 41 pin Amphenol socket 
located  on the front of the charger panel and charger lead socket to the 
HAWK battery charge input plug. 
 
The charger is ready for use. 
 
 

 

 

 

Summary of Contents for RMBC64-24D HAWK

Page 1: ...RMBC64 24D HAWK 3 STAGE BATTERY CHARGER OPERATORS MANUAL 2012...

Page 2: ...RMBC64 24D ELECTRONIC BATTERY CHARGER INDEX Page Handling Requirements 1 Installation 1 Specifications 2 Overview 3 Functional Description 3 Operation 5 Trouble Shooting 11...

Page 3: ...tch is in the OFF position Lower back flap by twisting anti clockwise Zuse fasteners to expose mains input socket and ventilation fans Ensure both charger and mains is switched OFF before connecting p...

Page 4: ...570mm H x W x D Battery charge state Any level from flat to full Time between full charge operation 1 hour Time between full charge operation means that if the operator has fully charged the battery i...

Page 5: ...l be on with the top row of green LEDs flashing This indicates that all the charging circuits are operating correctly within the bank When the charge cycle is complete the red LEDs within that bank wi...

Page 6: ...Vss provides the necessary signal to the servo control loop which regulates the charging current The charger unit consists of two banks of sixteen individual chargers each delivering 0 3C at full cha...

Page 7: ...HAWK batteries together Various combinations of battery charge can be selected which include A Single battery on full charge B Two batteries on full charge C One battery on full charge and second batt...

Page 8: ...rcuits have been internally checked and they are operating correctly After the charge procedure has been initialized the charge indicators will start to flash and continue to flash until the battery i...

Page 9: ...ators representing the selected battery will illuminate and remain constant for as long as it takes to charge the appropriate cells When the cells are fully charged the appropriate status indicators w...

Page 10: ...ition informs the operator when the trickle charge system is in operation by emitting an audible intermittent bleep This alert can also be used to remind the operator when the batteries have completed...

Page 11: ...rocedure the LED will go out informing him her that the trickle procedure has stopped After the HAWK battery has been fully charged the main charging system turns off and the trickle charge commences...

Page 12: ...or The power indicator lamp informs the operator when illuminated that mains power is being supplied to the charger 12 Fuse An 8AMP Anti Surge fuse is fitted to this charger WARNING THIS CHARGER IS FO...

Page 13: ...p fuse not illuminated Check power from source Charger has power WARNING CHARGER MUST BE Neon mains light Charger fuse blown SWITCHED OFF FROM THE MAINS illuminated but not BEFORE OPENING FUSE HOLDER...