Warranty Agreement

Limited Warranty

Advanced Thermal  Solutions, Inc. (hereinafter “ATS”) warrants that: (1) the ATS-Chill V  
Series chillers will perform in accordance with the written materials for a period of ninety  
(90) days from the date of purchase; and (2) Software will be free from defects and errors  
in materials and workmanship, and covered for a period of ninety (90) days from the date  
of purchase if utilized under normal use and service.  Any implied warranties on the Software  
are limited to ninety (90) days.

Customer Remedies

ATS and all its suppliers’ entire liability and the consumer’s exclusive remedy shall be at ATS’s 
option, either for the return of the price paid or the repair and replacement of the Software or 
Hardware that does not meet the limited warranty and which is returned to ATS. The limited 
warranty is deemed to be null if the failure of the Software and accompanying material results 
from an accident, abuse, and/or misapplications.  Any replacement of the Software and 
accompanying material will be warranted for the remainder of the original warranty period or thirty 
(30) days, whichever is longer.
ATS and its suppliers disclaim any and all other warranties, whether expressed or implied, 

including but not limited to implied warranties of merchant ability and fitness for a particular 

purpose, with regard to the Software and accompanying written and Hardware material.  This 

limited warranty provides you with specific legal rights; however, you may have other rights which 

would vary from state to state.
In no event shall ATS or its suppliers be liable for any damages whatsoever arising out of the use 
of or inability to use this product, even if ATS has been advised of the possibility of such damages.  
However, some states do not allow the exclusion or limitation of liability for incidental damages, 
hence this limitation may not apply.
NO LIABILITY FOR CONSEQUENTIAL DAMAGES. In no event shall ATS or its suppliers be 
liable for any damages whatsoever (including, without limitation, damages for loss of business 

profits, business interruption, loss of business information, or other pecuniary) loss arising from 

the use of or inability to use this ATS product, even if ATS has been advised of  the possibility of 
such damages.

COPYRIGHT

The ATS-Chill V Series and its operating software is patent pending and proprietary to Advanced 
Thermal Solutions, Inc. 

DISCLAIMER

While every effort is made to ensure accuracy, Advanced Thermal Solutions, Inc, cannot be held 
responsible for errors or omissions in this Manual. Furthermore, it reserves the right to revise this 
document and make changes without notice.

Summary of Contents for Chill V Series

Page 1: ...ATS Chill V Series Re CirculatingChiller Instructional Manual 89 27 Access Road Norwood MA 02062 T 781 769 2800 F 781 769 9979 www qats com ATS Chill V Series...

Page 2: ...including but not limited to implied warranties of merchant ability and fitness for a particular purpose with regard to the Software and accompanying written and Hardware material This limited warrant...

Page 3: ...Contents 1 Safety Notes 3 2 Unpacking 3 3 Equipment Description 3 4 Brief Instructions 4 5 Operating Panel 5 6 Technical Data 8 7 Maintenance 8 Table of Contents...

Page 4: ...or servicing or repair before moving the equipment Drain the bath before moving the equipment Have the equipment serviced or repaired only by properly qualified personnel Other ATS Liquid Cooling Prod...

Page 5: ...cooled through a heat exchanger located inside the bath Heat of condensation and motor heat are dissipated on air cooled units through a fan cooled ribbed condenser The refrigeration unit is protecte...

Page 6: ...the pressure connection should be left open when the equipment is filled for the first time otherwise there may be permanent damage to the pump Remove the plug on the filler opening at the upside A f...

Page 7: ...contact Check the details on the rating label against the supply voltage No warranty applies when the equipment is connected to the wrong supply 4 4 Emptying Place a container underneath the drain co...

Page 8: ...Lamp AUTO Auto Optimize Auto tuning OVER Over temperature alarm LEVEL Low Level alarm Option Operation Description Basal display status When powered on the upper display window of the instrument shows...

Page 9: ...e several seconds to several hours After the auto tuning finishes the parameter At automatically changes to OFF If the user wants to run auto tuning again set the setting parameter from At to on Note...

Page 10: ...p Flow Rate 7 10 L min 15 L min 10L min 10 L min Working mode Continuous Continuous Continuous Continuous Filling Port mm 25 25 25 25 Reservoir Capacity 1 0 L 4 5 L 8 L 8 L Dimensions W x D x H 230 x...

Page 11: ...here the condenser of the refrigerator has to be cleaned at intervals of 4 to 6 months or more frequently This is best done by blowing compressed air or nitrogen into the ventilation openings for a fe...

Page 12: ...ality test equipment s and leading edge R D specifically tailored to the telecom LED and computing industries In addition ATS provides thermal design consulting services and training for the electroni...

Reviews: