APD series bench scale
APD_01_11.05_EN_U
15
9.2 REACTIVATION OF THE TOTALISATION
To avoid undesired totalisations, the
M+
key is active just once; its reactivation depends on the setting of the “rEACt”
parameter
(TECH.MAN.REF.)
in the setup environment. It can be reactivated after the passing of the weight by the zero of
the scale, by instability of the weight or always.
If the reactivation on instability has been set, the totalisation is reactivated by instability of the weight with manual
totalisation or by instability and change in weight of 10 or 20 divisions (respectively with not approved or approved
instrument) with automatic totalisation.
By pressing the
M+
key again,
without having reenabled the totalisation
, the "no.0.unS" error message is displayed and
an acoustic signal is emitted.
NOTES:
-
If the gross or net weight in absolute value is less than the requested minimum weight, by pressing the
M+
key the
display shows the “LoW” error message.
-
If the scale is in the under load or over load status, by pressing the
M+
key the display shows the “un.oVEr” error
message.
9.3 VISUALIZATION OF THE TOTAL
By pressing the MR key one can temporarily view on the display the number of weighs and the net weight total. If the total
weight has more than 6 digits, the visualisation of this value takes place in two stages.
9.4 ZEROING OF THE TOTAL
The instrument increases the total weight upon each totalisation; it can be cleared in the following modes:
- by executing the
Mc
(memory clear) function: press in rapid succession the MR and MODE keys (the “tot.Clr” message is
displayed);
- by executing the conversion of the unit of measure;
- by turning off the instrument;
- automatically after having carried out the number of totalisations set in the
<<MAX.tot>>
step.