background image

 

 

Professional Weighing 

 

Equipment 

 

 

 

 

 

 

 

 

 

 

 

PIZA Series Bench Weighing Scale 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PIZA 12 

 

 

 

PIZA 25 

 

 
 

             Operation Manual 
 

 

 

Summary of Contents for PIZA 12

Page 1: ...Professional Weighing Equipment PIZA Series Bench Weighing Scale PIZA 12 PIZA 25 Operation Manual ...

Page 2: ...e 4 Introduction 5 Safety 6 Weight Scale 7 Functions 8 Features 9 Application Conformity 10 Getting Started 11 Delivery 11 Assembly Installation 12 Indicator Description 13 Function Settings 14 Hold Function 15 RS232 16 Calibration 17 Maintenance Service 18 Transportation Storage 18 Warranty 19 ...

Page 3: ...uct to which this declaration refers conforms to the following standards Electronic scale WPB High Resolution Balances USA model UK Europe model PIZA 12 PIZA 25 Mark applied EU Directive Standards 2004 108 EC EN 61326 1 2006 Signature Boon Lim R D Manager Date 14 11 2012 LW Measurements LLC 620 Carlson Court Rohnert Park CA 94928 ...

Page 4: ...lson Court Rohnert Park CA 94928 USA Tel 707 542 2185 FAX 707 542 3285 http lwmeasurements com EUROPE LW Measurements Europe Ltd Chalkwell Park House 700 London Road Westcliff on Sea Essex SS0 9HQ United Kingdom Tel 01702 476700 Fax 01702 477380 http lwmeasurements com ...

Page 5: ...hese operating instructions in their entirety so that you can make optimum use of the full potential and the diverse possibilities of the weighing scale in your daily work These operating instructions contain guidance in the form of pictograms and keyboard diagrams which should help you in finding the required information For the labeling of potential hazards and advice please see Safety below ...

Page 6: ... scale it should be immediately unplugged from the electricity supply pull out power adapter and secured against inadvertent operation In carrying out maintenance work it is essential to follow the recommendations set out in maintenance and servicing The weighing scale must not be operated in an area subject to explosion risks Care must be taken when weighing liquids to ensure that no liquid is sp...

Page 7: ...106 7 Weight Scale Construction Functions The weighing scale consists of the following parts Weight scale body 1 The scale pan 2 Foot switch 3 Indicator 4 The adapters 5 Operating manual Figure your scale 1 3 2 5 4 ...

Page 8: ...ze PIZA 12 12 lb 0 002lb 12 2 x 12 5 in 320 x 310 mm PIZA 25 25 lb 0 005lb 12 2 x 12 5 in 320 x 310 mm Net gross weight 5 6kg 12 4lb 6 4kg 14 1lb l Package 1 Unit in one box Standard carton 508x370x140 mm 20 x 14 6 x 5 5 in Package 4 Units in one box Master carton 525 x 610 x 393 mm 20 6 x 24 x 15 5 in Operating Temp 0 40 32 104 6 x AA dry cells not included or AC DC Power source Adapter 9V 100mA ...

Page 9: ...5 2106 9 Features Auto shut off selectable Auto zero tracking Large LCD Large weighing platter AC Power Beeper Foot switch Auto calibration AnyCal Software Auto backlight selectable Details of your weighing scale ...

Page 10: ...for the safe use of the relevant attachments and their application in accordance with instructions must be observed The weighing scale has been manufactured and tested in accordance with the standards and recommendations set out in the declaration of conformity The power adapter supplied for the weighing scale complies with the appropriate electrical protection class The following applies to PIZA ...

Page 11: ...for a couple hours and kept in its box in a dry room at normal temperature so that no condensation settles on the unit when opening the box Check the scale immediately after unpacking for any external visual damage If there is any damage on scale contact customer service immediately If the scale is not to be used immediately after purchase it should be stored in a dry place where fluctuations in t...

Page 12: ...the operating voltage is not the same as the mains voltage the power adapter must not be connected to the mains socket and contact customer service Placement of Scale The location in which the scale is placed is very important in order for the scale to work to its full potential Certain conditions can affect the capabilities of the scale conditions like the presence of air flow variations in tempe...

Page 13: ...ZERO for TARE This key is Zero feature if load is below 10 of full capacity or a negative value and is tare function between 10 to full capacity It has multiple tare function but total weight of before and after Tare must be less than its full capacity 5 PRINT Press once and send weight information once 6 Foot Switch With the same functions as ZERO key ON OFF HOLD ZERO UNIT PRINT ...

Page 14: ...showing the weight placed when turning on the power Press UNIT key the display will show F Nor F PEA or F Ani Press ZERO key to select Nor or PEA or Ani Nor means normal weighing function activate PEA means peak hold weighting function activate Ani means animal weighting function activate not recommended on or around food preparation Press UNIT key the display will show N dsp or N Ind Press ZERO k...

Page 15: ...or will turn on Remove the item from scale platter the item s weight reading will remain on the display Now you can also select units by pressing UNIT key Quit HOLD function Once an item is weighed and hold function is enabled you want to quit HOLD function press the HOLD key again to cancel the hold indicator and return the scale to weighing mode ...

Page 16: ...nsmission 57H 3AH P Polarity 2BH Positive 2DH Negative DATA 12 345 20H 20H 20H 20H 31H 32H 2EH 33H 34H 35H UNIT g 67H 20H 20H 20H 20H oz 6FH 7AH 20H 20H 20H lb 6CH 62H 20H 20H 20H dwt 64H 77H 74H 20H 20H ozt 6FH 7AH 74H 20H 20H ct 63H 74H 20H 20H 20H tl T 74H 6CH 2EH 54H 20H tl H 74H 6CH 2EH 48H 20H tl J 74H 6CH 2EH 4AH 20H GN 47H 4EH 20H 20H 20H dr 64H 72H 20H 20H 20H MM 4DH 4DH 20H 20H 20H tola ...

Page 17: ...ey again the display will show CAL press UNIT key to calibration weight Press UNIT key to move the flash digit to right then press ZERO key to increase the flash digit press HOLD key to confirm the selection the calibration weight should be more than 2 3 of full capacity it will show CAL Press PRINT it will show CAL and AD value Press UNIT key the display will show the flash calibration weight pla...

Page 18: ... a soft lint free cloth moistened with a mild soap solution Never use solvents acids alkalis paint thinners scouring powders or other aggressive or corrosive chemicals for cleaning these substances can cause damage to the surfaces of the scale housing Transport Storage Your weighing machine is a precision instrument treat it carefully Avoid shaking severe impacts and vibration during the transport...

Page 19: ...nal box If they are not properly packed an in the original box the customer pays for shipping cost If we determine there is a factory defect we will pay for the shipping back If we determine that it is not a factory defect the customer will pay shipping For Customers outside the lower 48 States including Mexico Canada Puerto Rico Hawaii Alaska and all other countries customers must pay for shippin...

Page 20: ...Rev 2 07 25 2106 20 ...

Reviews: